Cartridge Performance Data
Performance Data
Substance
Guidelines*
Average
Influent
Concentration
Max Effluent
Concentration
Min Percent
Removal
Average
Effluent
Concentration
Average
Percent
Removal
NSF Standard 42 Drinking Water Treatment Units
Chlorine
(23,000 L)
5 - Health
0.6 - Aesthetic
2.1
0.3
50%
0.25
>94%
Standard 53 Cyst Live Cryptosporidium POU/POE
Cyst
<1
100,000
ND (1)
99.98% +
ND (1)
99.99%
Test Parameters
Hardness, Total mg/L
120
TDS mg/L
290
Temp deg C
21°C
Turbidity NTU
0.1
pH
7.57
*Australian Drinking Water Guidelines - 1996
ND = Not Detected
This appliance meets the domestic water treatment appliance Standards AS/NZS3497 for the following
water treatment processes:
Class
Treatment type
Function
Pass
I
Microbiological Status
Bacteriostatic
Will stop bacteria increasing, but will not
remove them unless II(a) is passed
N/A
II
Microbiological Treatment
II (a)
Bacteria Removal
Will remove or inactivate bacteria
YES
II (b)
Virus Removal
Will remove or inactivate virus
YES
II (c)
Protozoa Removal
Will remove or inactivate Cryptosporidium
and Giardia, but will not remove or
inactivate bacteria and virises unless II(a)
and II(b) is passed
YES
III
Turbidity & Particulate Reduction
Reduces cloudiness
YES
IV
Taste & Odour Reduction
Reduces taste & odours
YES
V
Chemical Treatment
Decreases chlorine
YES