PART 2
Filter Installation
This system comes complete with an installation kit enabling it to be connected to 15mm
(½”) male thread.
Installation requirements
1. 15mm (½”) Cold water line - mains only
2. Min/Max pressure: 172 - 875 kPa. Pressure over 500 kPa requires a pressure limiting
valve to be installed.
Replacement of Ceramic Disc Cartridge(s)
1.
Hot/Cold Outlet
• Remove hot and cold water indicator then release screw in lever and lift lever off, now
you can unscrew dome cap and loosen the cartridge lock nut.
• Lift out old cartridge and clean inside making sure no old O-rings are still stuck inside
cartridge housing.
• Insert new cartridge making sure O-rings on bottom of new cartridge have not fallen
off and lugs in bottom of cartridge line up with holes in cartridge housing.
• Now you can tighten lock nut with a torque wrench to 14 newton meters, then reinstall
dome cap, lever screw and hot and cold water indicator.
2.
Filtered/Rain Ancillary Outlet
• Remove front button cover using fine-edged 1.2mm screwdriver.
• Unscrew handle then remove cartridge by unscrewing it anti-clockwise, using 5/8”
socket. Install cartridge by completing removal instructions as above, in reverse order.
• Ensure cartridge is firmly tightened not over tightened.
Replacement of Ceramic Disc