11
Quick Twist Water Filter System with Tripla LED Mixer Tap
Installation Procedure
3. Supply temperature 0° - 38°C (protect from freezing).
4. Suitable location for faucet.
Alternative fittings may be required if being connected to anything other than
existing 15mm (½”) copper pipe (coppy piper NOT included). No electrical or drainage
requirements needed.
Installation Procedure
Installation Note
: A water filter system/tap, like any product, has a limited life and may
eventually fail. Also sometimes failure happens early due to unforeseen circumstances.
To avoid possible property damage, this product should be regularly examined for leakage
and/or deterioration and replaced when necessary. A drain pan, plumbed to an appropriate
drain or outfitted with a leak detector, should be used in those applications where any
leakage could cause property damage, and/or the water supply should be turned off if no
one is home/present.
INSTALLATION MUST BE COMPLETED BY A LICENCED PLUMBER. FAULTY
OPERATION DUE TO UNQUALIFIED PERSONS WILL RESULT IN VOIDED
WARRANTY COVERAGE.
1. Select suitable location that is close to the point of filtered water delivery (eg. sink).
Remember to allow access room for changing filters and a suitable place where water
spillage will not cause damage. Location should not be in direct sunlight.
2. Isolate water supply and fit SmartTee to the mains cold supply ready for Mixer and
Filtered water line connections.
3. Connect the SmartTee™ to the multivalve with a piece of white tubing (see Fig. 7).
4. Install filter cartridge by positioning it in the desired location, marking the position of
fixing hole and fixing with bracket screw. Z1 Tripla Series can be mounted horizontally
or vertically. Allow room for the connecting tubes. Ensure flow arrow on cartridge is in
direction of water flow.
6. Fit the stem to tube reducers into either side of the filter by pushing the fittings into
the 3/8"quick-connect fittings already installed on the filter head (for quick-connect
fittings see Fig. 6).
5. Fit tubing into 1/4" connectors (stem to tube reducers). Allow slack in the tubing.
Connect the tubing into the filtered water flexible hose securing with the nut found on
the flexible hose (plain). An alternative plain hose with a larger fitting connection is
supplied but required with the Z1 installation.