5
HYBRID-R TRIPLE SERIES
| Triple Filtration & Ultraviolet Disinfection All in One Unit
Installation Guide
Positioning your System
Choose a location with a structurally appropriate mounting position. Allow a chamber
length space above the unit for removal of the lamp and sleeve from the Radfire UV
system during servicing and 120mm below the housings for replacing the cartridges and
maintenance.
An isolation valve may be installed prior to the Hybrid-R Triple system to isolate the unit
for changing the cartridges, lamps and sleeve.
To protect your Hybrid-R Triple system make sure the site is frost free and has adequate
ventilation. Choose a location with adequate drainage and where water spillage will not
cause damage that may occur over time from leaking pipe joints or seals.
Power Surge Protection
An electrical power surge or spike can travel on the supply lines and cause serious
damage to your electrical equipment. The Radfire UV Electronic ballast has a fuse (not
replaceable) to protect the circuit. The fuse is not a lightning arrestor and may not
protect the Radfire if lightning or a very powerful surge hits the unit.
A suitable surge protection device should be used on all electrical equipment or warranty
may be voided.
Do not use long extension leads as they may cause substantial voltage drop and/or poor
lamp performance.
We recommend the use of an RCD or earth leakage circuit breaker
on the power
supply to your unit.