Replacement Procedure
Lamp Replacement Procedure
Prior to performing any work on the UV sterilizer, always disconnect the power
supply first.
1 Turn water off and release the water pressure.
Parts become hot during operation.
Allow to cool before servicing.
2 Disconnect the lamp connector and ground
wire. Grip the end of the lamp and carefully
disconnect the power socket.
Slowly remove the old lamp from the chamber.
3. Remove the packaging on the new lamp. Slowly
insert into chamber through the hole of the
aluminium nut end. Connect the lamp connector
to the pins on the lamp. Do not let go of the lamp until the lamp is connected to the
socket (
see fig. 9-2
).
Never touch the quartz (glass) and lamp surface as marks or fingerprints may
interfere with UV transmission. If lamp is soiled, please clean lamp with an alcohol
based cleaner.
4. Secure the safety cap on the aluminium nut end. Connect the ground wire to the
chamber. Plug in power connector. (Make sure that the GREEN LED is illuminated).
5. Restore water supply and check the unit for leaks. Re-check the unit after 1 hour.
Note: For initial use, wait 3-5 minutes to allow water to pass through the whole
unit. Turn on a downstream tap to let water flow through the unit for 2-3 minutes to
release air and impurities from system.
6 Reset the lamp timer by pressing the mode button until an audible “beep” sounds
indicating that the lamp timer has been reset for a further 12 months.
We recommend replacing UV lamp annually to ensure high sterilizing rate with best
water quality.
Always keep UV lamp on, as power fluctuation will shorten the service life of the UV
lamp.
Cleaning Quartz Sleeve
1
2
3
valve
IN
OUT
10
mins
4
5
6
Replacing UV Lamp
7
8
9
Replacing UV Lamp
valve
IN
OUT
1
2
3
4
5
O Ring
3
O Ring
Cleaning Quartz Sleeve
1
2
3
valve
IN
OUT
10
mins
4
5
6
Replacing UV Lamp
7
8
9
Replacing UV Lamp
valve
IN
OUT
1
2
3
4
5
O Ring
3
O Ring