HYBRID-R TRIPLE SERIES
| Triple Filtration & Ultraviolet Disinfection All in One Unit
SYMPTOMS
POSSIBLE CAUSE
POSSIBLE SOLUTION
No power
Ballast and/or breaker tripped
Ballast damaged
Reset ballast and/or breaker
Replace ballast
Ballast or breaker
repeatedly trips
Connection between lamp and
lamp plug is wet
Short-circuit in the electrical
assembly
Clean and dry lamp pins and
lamp plug, check unit for leaks
or condensation
Replace ballast
Leak at inlet or
outlet
Threaded pipe fittings are leaking
Cracked heads
Clean threads, reseal with
Teflon tape and retighten
Replace heads
Leak detected
from area of UV
chamber
Condensation of moist air on cold
chamber (slow accumulation)
O-ring damaged, deteriorated or
incorrectly installed
Lamp/sleeve assembly not
properly installed (too tight or not
tight enough)
Control humidity or relocate unit
Inspect and replace if
deteriorated
Check O-rings are in place
Tighten assembly hand-tight
System is
operating but
water tests
reveal bacterial
contamination
Equipment downstream of UV
system is acting as a breeding
ground for pathogens
Pathogens are residing in the
distribution lines post-UV
Lamp reached the maximum lamp
life
Ensure UV is the last piece of
treatment equipment Ensure
all distribution lines have been
disinfected - see page 10
Remove any pipe dead-ends
and flush with chlorine
Replace lamp on or before lamp
counter reached 0.
Lamp timer does
not read anything
Unit is unplugged
No power at AC power outlet
Power cord is damaged
Power surge caused damage to
electrical assembly
Plug unit into AC power outlet
Replace fuse or reset breaker
Replace power cord
Replace ballast
Troubleshooting Guide