PureLink by Dtrovision
11
EDID Set
i)
Internal EDID Write
On this menu, select an EDID from the library and save it on to the Input EEPROM. UX series
Matrix Switcher has 13 selectable most widely used EDID data pre-programmed.
Select Internal EDID using UP (Create) and Down (Preview) buttons
Select Input# where selected EDID data will be saved on to. Multiple Inputs can be selected at
once.
Push enter button to save
* “P” will display on the LCD when EDID is successfully saved, “F” will display on theLCD when
EDID is NOT successfully saved.
ii) External EDID Write
- This menu is to emulate EDID data from any display devices that are connected to the
Matrix Switcher's Output via copper cables and save it on to Matrix Switcher's Input EEPROM.
Select Output #
Selected Output's display device's EDID information will be displayed
Select Input# where selected EDID data will be saved on to. Multiple Inputs can be selected at
once.
Push enter button to save.
* “P” will display on the LCD when EDID is successfully saved, “F” will display on the LCD when EDID
is NOT successfully saved.
Switcher ID
- By setting different ID to the Matrix Switcher, up to 255 units of HX series Matrix Switcher can be
connected and operated in the same network either via serial or LAN communication. Switcher ID can
be set between 001 ~ 255.
* Factory default setting is 255
Note) Switcher ID is associated with commend control Protocol; therefore, it is important to remember
Matrix Switcher's current Switcher ID.
RS232
- There are four values those need to be set for serial communication; baud rate, data bits, stop bits,
and parity. Click and select each value using touch screen and push enter button to save.
Factory default (recommended) settings for serial communication are:
Baud rate - 19200
Data bits - 8
Parity - none
Stop bits - 1
Flow control
– none