CLEANING 

• 

Always unplug the unit before servicing in any way.

• 

The water temperature of the water remaining in the unit after use may be high, allow  

time for it to cool.

GENERAL CLEANING

• 

Inside the base of the unit. 

Pour excess water out of the unit. Wash out the unit with fresh  

water using the cleaning brush and a soft cloth as needed. 

Do not submerse the base of the  

unit into water, or allow water to enter inside the dry air exhaust port of the unit.

• 

Water tank. 

Empty water tank. Remove mist nozzle and clean the mist tube with fresh water  

and a light brush (bottle cleaning brush is recommended).  

• 

Outer surface of the unit. 

Wipe the surface of the unit with a soft, damp cloth if needed. If 

you notice an accumulation of water during usage, reduce humidity and dry outer surface with 

a cloth. 

DESCALING

• 

Depending on usage and water type, cleaning to remove scale may be required 

weekly or every other week to optimize unit performance. 

•  If you live in a hardwater area, we recommend the use of distilled water for your    

humidifier. This will help reduce the precipitation of minerals or ‘white dust’.

•  Do not clean the unit or water tank with detergents or cleaning chemicals of any kind.

ULTRASONIC DISK

1.

 Unplug unit.

2.

 Remove the tank and empty all water from unit base and tank.

3.

 Locate the ultrasonic disk on the inside center of the base unit. (see pg. E-4)

4. 

Use ONLY the enclosed cleaning brush to 

gently

 clean disk and remove build up and deposits.  

  (Fig. 1) 

Do not scrub or scrape the ultrasonic disk.

E-8

E-9

CLEANING

CLEANING

If scale becomes difficult to remove with brush:
1.

 Fill the Base with: mixture of 1 tsp. white vinegar and 1 tsp. water.

2.

 Let solution stand for 5 minutes.

3.

 With the vinegar in the Base, clean all interior surfaces with a soft cloth or brush to help 

remove scale.

4.

 Also check mist nozzle and mist tube in water tank. Clean as needed.

5.

 Rinse the Base thoroughly with water to remove scale and vinegar solution.

If you have frequent scale build up and/or white dust, you can consider a decalcification 

cartridge (model FLTDC) available at www.guardiantechnologies.com or through

customer service 1.866.603.5900. 

END OF SEASON STORAGE

• Follow the Cleaning and Descaling instructions when the humidifier will be stored at the end 

of the season.

• Dry the humidifier completely before storing. DO NOT store with water inside the Base or 

Water Tank.

• 

Pack the unit in its original carton and store in a cool, dry location. 

NOTE: IF YOU EXPERIENCE A PROBLEM DO NOT ATTEMPT TO OPEN THE MOTOR 

HOUSING YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE 

TO THE HUMIDIFIER OR PERSONAL INJURY.

(Fig. 1)

*Clean the disk with the 

 

  brush only. No other  

  cleaning tool should  

  be used. BRUSH ONLY. 

 

  (Fig. 1)

Ultrasonic Disk

Содержание H4610

Страница 1: ...Purchased month _________ year __________ USE CARE INSTRUCTIONS Guardian Technologies LLC 7700 St Clair Avenue Mentor Ohio 44060 1 866 603 5900 www guardiantechnologies com English E 1 French F 1 Spa...

Страница 2: ...of time Unplug the cord when unit is not in use for an extended period of time and or when no one is home Do not keep water in the tank when not in use for an extended period of time READ AND SAVE THE...

Страница 3: ...midifier to automatically turn off in 4 8 or 12 hours POWER Turns humidifier ON OFF MIST CONTROL The spray volume or amount of mist that is produced by the unit can be adjusted to three levels based o...

Страница 4: ...ist When warm is selected LED will light Water temperature is maintained at room temperature for cool setting and 80 degrees for warm Allow 15 minutes for water to warm 5 Water Refill Indicator When t...

Страница 5: ...it base and tank 3 Locate the ultrasonic disk on the inside center of the base unit see pg E 4 4 Use ONLY the enclosed cleaning brush to gently clean disk and remove build up and deposits Fig 1 Do not...

Страница 6: ...compliance LIMITED WARRANTY E 10 E 11 PROBLEM SOLUTION Water vapor and humidity are not produced Power Plug Unplug and then try again Power Failure When the power is returned try again Tank Installati...

Страница 7: ...ique Mod le n H4610 Garantie limit e de trois 3 ans www guardiantechnologies com 1 866 603 5900 R V 0513 Date d achat mois __________ ann e _________ UTILISATION ET INSTRUCTIONS D ENTRETIEN Anglais E...

Страница 8: ...dessous peut provoquer une d charge lectrique ou des blessures graves LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENTS Le non respect des avertissements mentionn s ci dessous peut provoquer une d c...

Страница 9: ...S BOUTONS DU PANNEAU DE COMMANDE CARACT RISTIQUES CL S VEILLEUSE Une DEL illumine le r servoir d une lueur douce MINUTERIE Permet de r gler l arr t automatique de l humidificateur 4 8 ou 12 heures MAR...

Страница 10: ...llumer 2 Minuterie Appuyez sur le bouton de la minuterie pour s lectionner une dur e de 4 8 ou 12 heures L appareil s teint automatiquement au bout de cette dur e 3 Bouton de r glage de la vaporisatio...

Страница 11: ...r et au centre de la base de l appareil cf p F 4 4 Utilisez UNIQUEMENT la brosse de nettoyage incluse pour nettoyer doucement le disque et retirez les d p ts de mati re Fig 1 Ne frottez pas et ne grat...

Страница 12: ...ez le pour le vider avant de le transporter Niveau de bruit accru L appareil doit tre plac sur une surface de niveau plane et stable Assurez vous que l appareil n est PAS plac sur une surface instable...

Страница 13: ...tras nico Modelo No H4610 Garant a limitada por 3 a os www guardiantechnologies com 1 866 603 5900 REV0513 Fecha de compra mes___________ a o ___________ INSTRUCCIONES DE USO Y CUIDADO Ingl s E 1 Fran...

Страница 14: ...el ctrico o lesiones severas LEA Y GUARDE ESTAS INSTRUCCIONES ADVERTENCIAS El no cumplir las advertencias que se enumeran a continuaci n puede provocar un choque el ctrico o lesiones severas Desconect...

Страница 15: ...NTROL FUNCIONES DESTACADAS LUZ NOCTURNA Una luz LED ilumina el dep sito con una luz nocturna que emite un tenue resplandor TEMPORIZADOR Programe el humidificador con anterioridad para que se apague de...

Страница 16: ...para activar la luz nocturna 2 Temporizador Oprima el bot n del temporizador para seleccionar 4 8 o 12 horas La unidad se apagar a la hora que haya elegido 3 Bot n de control de neblina Cuando oprime...

Страница 17: ...terna de la base de la unidad vea la p g S 4 4 Use S LO el cepillo para limpieza incluido para limpiar cuidadosamente el disco y eliminar las incrustaciones y materiales depositados Fig 1 No frote ni...

Страница 18: ...vaciarlo antes de transportarlo Incremento del nivel de ruido La unidad debe colocarse sobre una superficie dura plana y nivelada Cerci rese de que NO est colocada sobre una superficie suave absorbent...

Отзывы: