![Pulsar QUANTUM3 Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/pulsar/quantum3/quantum3_instruction-manual_1624491068.webp)
Page
60
P102 Material
This parameter should be set to the type of material being monitored.
Option
Description
1 = Liquid (Default)
Use for liquids and flat solid materials
2 = Solid
Solid material that is heaped or at an angle
3 = Closed Tank
Used where material is contained in a closed
tank.
Dimensions
P104 Measurement Units
This parameter sets the units you want to use for programming and display
Option
Description
1 = metres (Default)
All units of measure are
METRES
2 = cm
All units of measure are
CENTIMETRES
3 = mm
All units of measure are
MILLIMETRES
4 = feet
All units of measure are
FEET
5 = inches
All units of measure are
INCHES
P105 Empty Level
This parameter is to be set to the
maximum distance
from the
face
of the
transducer to the
empty point
, in
P104
Measurement
Units
. Note this value
affects span as well, (see important information below), so should be set
before span.
Important Information
When using the
dB Mach 3
the
empty distance
is measured from the end
of the
horn
to the
empty point
in
P104 Measurement Units
.
Содержание QUANTUM3
Страница 1: ...QUANTUM 3 INSTRUCTION MANUAL ...
Страница 2: ......
Страница 4: ......
Страница 14: ...Page 6 EU Declaration of Conformity ...
Страница 17: ...Page 9 The full dimensions of the enclosure are as shown below ...
Страница 21: ...Page 13 ...
Страница 22: ...Page 14 ...
Страница 48: ...Page 40 This page left blank intentionally ...