![Pulsar FlowCERT LITE Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/pulsar/flowcert-lite/flowcert-lite_instruction-manual_1624670057.webp)
Page
49
BS3680 Thin Plate Weirs
Point of Measurement
The transducer must be above the
maximum head P704
by at least the near
blanking distance P107
.
For a
Rectangular
and
V-notch
weirs, the head is measured at a point 4 to
5
times
the
maximum head
upstream
from the weir plate, to ensure the
surface of the liquid is not affected by turbulence or drawdown.
(See
DRWG 8
)
Calculations
BS 3680 Rectangular Weir
A
BSOLUTE
If the flow calculation is to be
absolute
P702
=
1
the flow will be calculated
using the formula: q = C
e
2/3(2gn)
0.5
b
e
h
e
1.5
Where: q = flowrate
Ce
=
discharge coefficient
calculated by FlowCERT
LITE
P723
gn = gravitational acceleration (nominal value = 980.66 cm/s
2
)
be =effective approach width where
b
is
approach width
(
Dim“A”
)
P710
he = effective head