![Pulsar FlowCERT LITE Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/pulsar/flowcert-lite/flowcert-lite_instruction-manual_1624670048.webp)
Page 40
Calculations
A
BSOLUTE
If the flow calculation is to be
absolute
P702
=
1
the flow will be calculated
using the formula (s) as follows:
Exponent Type
Formula
Exponent
K Factor
Suppressed
Rectangular
Weir
(Without End
Contractions)
Q=KLh
x
Where:
Q =Flow
K=
K factor
L=crest length of weir
h=head
x
=
exponent
1.50
Automatically
selected by
FlowCERT
LITE
Automatically
calculated,
dependent on
measurement,
flow and time
units chosen.
Cipolletti
(Trapezoidal)
Weir
Q=KLh
x
Where:
Q =Flow
K=
K factor
L=crest length of weir
h=head
x
=
exponent
1.50
Automatically
selected by
FlowCERT
LITE
Automatically
calculated,
dependent on
measurement,
flow and time
units chosen.
Venturi Flume
Q=Kh
x
Where:
Q =Flow
K=
K factor
h=head
x
=
exponent
1.50
Automatically
selected by
FlowCERT
LITE
Enter value of
K Factor (P718)
as required
Parshall Flume
Q=Kh
x
Where:
Q =Flow
K=
K factor
h=head
x
=
exponent
Automatically
calculated
dependent on
throat size
(P719)
Automatically
calculated,
dependent on
throat size and
measurement,
flow and time
units chosen.
Leopold Lagco
Flume
Q=KD
0.0953
h
x
Where:
Q =Flow
K=
K factor
D=pipe diameter
h=head
x
=
exponent
1.55
Automatically
selected by
FlowCERT
LITE
Automatically
calculated,
dependent on
measurement,
flow and time
units chosen.
Содержание FlowCERT LITE
Страница 1: ...FlowCERT LITE UL INSTRUCTION MANUAL...
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 14: ...Page 6 EC DECLARATION OF CONFORMITY...
Страница 18: ...Page 10 The full dimensions of the enclosure are as shown below...
Страница 37: ...Page 29 This page left blank intentionally...
Страница 77: ...Page 69...
Страница 135: ...Page 127 This page left blank intentionally...
Страница 137: ...Page 129 This page left blank intentionally...