TTFM 6.1 INSTRUCTION MANUAL
54
SEPARATION DISTANCE (Sensor Spacing Distance)
Separation distance is automatically calculated by the TTFM 6.1 based on parameters entered in the Setup menu.
Sens Space is a parameter where this distance is given, and it is located in the Setup menu. Document this value
for the following transducer installation procedure.
1 CROSS INSTALLATION OVERVIEW – SE16B Transducers TMK-B21 or TMK-B22 Kit
To assist with the proper installation of the transducers in a 1 cross installation, we provide a kit with every meter,
which consists of the following:
Sanding block
Tape measure
Mylar sleeve
Duct tape
Level
Black Sharpie
Follow along with the 1 cross installation instructions on the following pages for a description of where to use
these tools.
1. Prep the pipe per instructions on page 29 and mind the installation location requirements on page 32.
Clean the location where the sensor is to be mounted on the opposite side of the pipe after we’ve marked
where it will be installed. The picture below shows a very clean ductile iron pipe which did not require
much cleaning.