![Pulsar Measurement Greyline TTFM 6.1 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/pulsar-measurement/greyline-ttfm-6-1/greyline-ttfm-6-1_instruction-manual_1625415024.webp)
TTFM 6.1 INSTRUCTION MANUAL
24
SPECIAL FUNCTIONS
Press
or
to position curser at Special Functions, and
to enter. Use
or
to position cursor before each menu item and
to enter. When settings are
completed press
to store and
again to return to the Main Menu.
Language
Select
English
,
French
or
Spanish
Analog Out
Select 4-20mA or 0-5V mode for the analog
output.
Backlight
Select
High
,
Medium
or
Low
for
continuous backlight brightness.
Select
Key Hi/Lo
for high backlight lasting
1 minute after a keypress, and then Lo
backlight until a key is pressed again.
Select
Key High
,
Med
or
Low
for
backlight lasting 1 minute after a keypress and
then backlight off until a key is pressed again.
Reset Totalizer
Select
Yes
to erase and restart the totalizer at
zero.
Negative Totals
Select
Yes
to have reverse flow readings
deducted from the totalizer. Select
No
to
totalize forward flow only and ignore reverse flow.
Rev. Flow
Select
On
to enable flow direction
measurement. Select
Off
to disable flow
direction measurement so that flow in either
direction is displayed and output as positive
values.
Select
Invert
to invert the sense of the flow
measurement.
Capture Par
This function captures the programming
parameters in the meter. Select
Yes
, wait for
Insrt USB
to appear, then insert a USB drive
into the USB port to transfer the parameters. After
Saving flashes,
Done
will appear on the screen,
meaning it is safe to remove the USB.
--Special Functions-
Language
English
Analog Out
4-20mA
Backlight
High
Reset Totalizer
NO
Neg. Totals
NO
Rev. Flow
OFF
Capture Par
NO
Capture WF
NO
Restore Defaults
NO
New Password
0000