◦
+3V
SB1
SB2
COM
SEN3
SEN2
REF
+3V
SB1
SB2
COM
+3V
SB1
SB2
COM
◦
◦
◦
◦
PSG Controls, Inc.
LIMITED WARRANTY POLICY
PSG Controls, Inc. (Hereinafter referred to as "PSG") warrants the following:
Only cataloged products sold to distributors are warranted to the original purchaser,
to conform with specifications furnished or approved by PSG, and to be free from
defects in material and workmanship, for a period of one (1) year from the date of
purchase, unless specified in writing for a different period.
Any PSG product that proves defective within the above described warranty period
will be repaired or replaced (at PSG's option) free of any charge if returned to the
PSG factory at 1225 Tunnel Road, Perkasie, PA. 18944 with transportation charges
prepaid. Prior to returning this product to PSG, the purchaser shall give PSG notice
in writing stating how this product fails to fulfill this warranty. No product shall be
accepted for repair or replacement without a required written notice and without
prior written authorization and shipping instructions having been received by the
purchaser from PSG. Only PSG's factory is authorized to perform services under
this warranty.
This warranty does not extend to any product that has been subjected to misuse,
abuse, neglect, accidents, alterations, improper installation or use in violation of the
printed instructions furnished by PSG. This warranty neither applies to batteries nor
deterioration of, nor damage to the product caused by the use of faulty batteries.
Final determination as to whether any product is actually defective rests solely with
PSG.
This warranty is expressly in lieu of all other agreements and warranties,
expressed, implied, or statutory and PSG has no other obligations or liabilities in
connection with this product. In no event shall PSG's obligation or liability
hereunder exceed the purchase price of this product. PSG SHALL NOT IN ANY
EVENT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES.
This warranty gives you specific legal rights, and you also have other rights which
vary from state to state. Some states do not allow the exclusion or limitation of
incidental or consequential damages, or implied warranties, so the above limitations
or exclusion may not apply to you.
Toll free technical assistance is available
via our technical hotline: 1-800-523-2558
Mon-Fri, 8:00 A.M. to 4:30 P.M. Eastern Standard Time
1225 Tunnel Road - Perkasie, PA 18944 - 215-257-3621 - Fax 215-257-4288
Web site - www.psgcontrols.com E-mail - [email protected]
R
PSG Controls, Inc.
6
9510-0712
Rev D 10-23-07
2Ps Functions:
System with a single valve used for hear and cool.
The cooling wire of the thermostat will be used to control the water
valve for heat and cool.
The heat wire will not be used.
FUNCTION CHART 2Ps
Adjust setpoint as follows:
6.0°F or more ABOVE room temperature
3.0°F up to 5.9°F ABOVE room temperature
0.4°F BELOW to 2.9°F ABOVE room temperature
more than 0.4°F BELOW room temperature
Hot Pipe
MED
Lo
Hi Med
Lo
Med Med
Lo Med
Lo
Off Med
HIGH
Hi
Hi
Hi
Hi
On
On
On
Off
LOW
AUTO
VALVE
FAN SPEED
Lo
Adjust setpoint as follows:
more than 0.4°F ABOVE room temperature
3.0°F down to 5.9°F BELOW room temperature
0.4°F ABOVE to 2.9°F BELOW room temperature
6.0°F or more BELOW room temperature
Cold Pipe
MED
Lo
Off Med
Lo
Lo Med
Lo Med
Lo
Hi Med
HIGH
Hi
Hi
Hi
Hi
Off
On
On
On
LOW
AUTO
VALVE
FAN SPEED
Med
2Pn Functions:
System is valveless.
Heating and cooling are provided by operating fans only. The
cooling wire of the thermostat will operate similiarly to the 2Ps
above, but it is not necessary for connection.
The heat wire will not be used.
FUNCTION CHART 2Pn
Adjust setpoint as follows:
6.0°F or more ABOVE room temperature
3.0°F up to 5.9°F ABOVE room temperature
0.4°F BELOW to 2.9°F ABOVE room temperature
more than 0.4°F BELOW room temperature
Hot Pipe
MED
Lo
Hi Med
Lo
Med Med
Lo Med
Off
Off *Off
HIGH
Hi
Hi
Hi
*Off
On
On
On
Off
LOW
AUTO
VALVE
FAN SPEED
Lo
Adjust setpoint as follows:
more than 0.4°F ABOVE room temperature
3.0°F down to 5.9°F BELOW room temperature
0.4°F ABOVE to 2.9°F BELOW room temperature
6.0°F or more BELOW room temperature
Cold Pipe
MED
Lo
Off *Off
Lo
Lo Med
Lo Med
Lo
Hi Med
HIGH
*Off
Hi
Hi
Hi
Off
On
On
On
LOW
AUTO
VALVE
FAN SPEED
Med
2PE Functions:
System with a single valve that supplies both hot and cold water and
has an auxiliary electric strip heat for use when pipe is cold.
The cooling wire of the thermostat will be used to control the water
valve for heat and cool.
The heat wire will operate auxiliary electric strip heat.
FUNCTION CHART 2PE
Adjust setpoint as follows:
6.0°F or more ABOVE room temperature
3.0°F up to 5.9°F ABOVE room temperature
0.4°F BELOW to 2.9°F ABOVE room temperature
more than 0.4°F BELOW room temperature
Hot Pipe
MED
Lo
Hi Med
Lo
Med Med
Lo Med
Lo
Off Med
HIGH
Hi
Hi
Hi
Hi
On
On
On
Off
LOW
AUTO
VALVE
FAN SPEED
Lo
AUX HT
SYSTEM
Adjust setpoint as follows:
6.0°F or more ABOVE room temperature
3.0°F up to 5.9°F ABOVE room temperature
1.9°F BELOW to 0.4°F BELOW room temperature
2.0°F BELOW room temperature (cool threshold)
Cold Pipe, Active auxiliary heat
MED
Lo
Hi Med
Lo
Med Med
Lo Med
Lo
Lo Med
HIGH
Hi
Hi
Hi
Hi
On
On
Off
Set
Reset
LOW
AUTO
VALVE
FAN SPEED
Off
AUX HT
SYSTEM
0.4°F BELOW to 2.9°F ABOVE room temperature
Lo Med Hi
On
Lo
Adjust setpoint as follows:
2.0°F ABOVE room temperature
1.9°F ABOVE to 1.9°F BELOW room temperature
Cold Pipe, Dynamic Dead Band
MED
Lo
Lo Med
Lo
Off Med
HIGH
Hi
Hi
Set
Off
Off
Set
Off
LOW
AUTO
VALVE
FAN SPEED
AUX HT
SYSTEM
2.0°F BELOW room temperature
Lo Med Hi
Lo
Cooling Currently Active
2.0°F ABOVE room temperature (heat threshold)
1.9°F ABOVE to 0.4°F ABOVE room temperature
3.0°F BELOW to 5.9°F BELOW room temperature
6.0°F or more BELOW room temperature
Cold Pipe, Active Cooling
MED
Lo
Lo Med
Lo
Off Med
Lo Med
Lo
Hi Med
HIGH
Hi
Hi
Hi
Hi
Set
On
On
On
Off
Reset
LOW
AUTO
VALVE
FAN SPEED
Med
AUX HT
SYSTEM
0.4°F ABOVE to 2.9°F BELOW room temperature
Lo Med Hi
Lo
◦
SEN3
SEN2
REF
+3V
SB1
SB2
COM
◦
◦
◦