background image

 

+3V 

SB1 

SB2 

COM 

SEN3 

SEN2 

REF 

+3V 

SB1 

SB2 

COM 

+3V 

SB1 

SB2 

COM 

 

 

 

 

PSG Controls, Inc.

LIMITED WARRANTY POLICY

PSG Controls, Inc. (Hereinafter referred to as "PSG") warrants the following:
Only cataloged products sold to distributors are warranted to the original purchaser, 
to conform with specifications furnished or approved by PSG, and to be free from 
defects in material and workmanship, for a period of one (1) year from the date of 
purchase, unless specified in writing for a different period.
Any PSG product that proves defective within the above described warranty period 
will be repaired or replaced (at PSG's option) free of any charge if returned to the 
PSG factory at 1225 Tunnel Road, Perkasie, PA. 18944 with transportation charges 
prepaid.  Prior to returning this product to PSG, the purchaser shall give PSG notice 
in writing stating how this product fails to fulfill this warranty.  No product shall be 
accepted for repair or replacement without a required written notice and without 
prior written authorization and shipping instructions having been received by the 
purchaser from PSG.  Only PSG's factory is authorized to perform services under 
this warranty.
This warranty does not extend to any product that has been subjected to misuse, 
abuse, neglect, accidents, alterations, improper installation or use in violation of the 
printed instructions furnished by PSG.  This warranty neither applies to batteries nor 
deterioration of, nor damage to the product caused by the use of faulty batteries.  
Final determination as to whether any product is actually defective rests solely with 
PSG.  
This warranty is expressly in lieu of all other agreements and warranties, 
expressed, implied, or statutory and PSG has no other obligations or liabilities in 
connection with this product.  In no event shall PSG's obligation or liability 
hereunder exceed the purchase price of this product.  PSG SHALL NOT IN ANY 
EVENT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES.  
This warranty gives you specific legal rights, and you also have other rights which 
vary from state to state.  Some states do not allow the exclusion or limitation of 
incidental or consequential damages, or implied warranties, so the above limitations 
or exclusion may not apply to you.

Toll free technical assistance is available

via our technical hotline: 1-800-523-2558

Mon-Fri, 8:00 A.M. to 4:30 P.M. Eastern Standard Time

1225 Tunnel Road - Perkasie, PA 18944 - 215-257-3621 - Fax 215-257-4288

Web site - www.psgcontrols.com              E-mail - [email protected]

 

PSG Controls, Inc. 

9510-0712
Rev D    10-23-07

2Ps Functions:

System with a single valve used for hear and cool.
The cooling wire of the thermostat will be used to control the water 
valve for heat and cool.
The heat wire will not be used.

FUNCTION CHART 2Ps 

Adjust setpoint as follows: 

6.0°F or more ABOVE room temperature 

3.0°F up to 5.9°F ABOVE room temperature 

0.4°F BELOW to 2.9°F ABOVE room temperature 

more than 0.4°F BELOW room temperature 

Hot Pipe 

MED 

Lo 

Hi Med 

Lo 

Med Med 

Lo Med 

Lo 

Off Med 

HIGH 

Hi 

Hi 

Hi 

Hi 

On 

On 

On 

Off 

LOW 

AUTO 

VALVE 

FAN SPEED 

Lo 

Adjust setpoint as follows: 

more than 0.4°F ABOVE room temperature 

3.0°F down to 5.9°F BELOW room temperature 

0.4°F ABOVE to 2.9°F BELOW room temperature 

6.0°F or more BELOW room temperature 

Cold Pipe 

MED 

Lo 

Off Med 

Lo 

Lo Med 

Lo Med 

Lo 

Hi Med 

HIGH 

Hi 

Hi 

Hi 

Hi 

Off 

On 

On 

On 

LOW 

AUTO 

VALVE 

FAN SPEED 

Med 

2Pn Functions:

System is valveless.
Heating and cooling are provided by operating fans only.  The 
cooling wire of the thermostat will operate similiarly to the 2Ps 
above, but it is not necessary for connection.
The heat wire will not be used.

FUNCTION CHART 2Pn 

Adjust setpoint as follows: 

6.0°F or more ABOVE room temperature 

3.0°F up to 5.9°F ABOVE room temperature 

0.4°F BELOW to 2.9°F ABOVE room temperature 

more than 0.4°F BELOW room temperature 

Hot Pipe 

MED 

Lo 

Hi Med 

Lo 

Med Med 

Lo Med 

Off 

Off *Off 

HIGH 

Hi 

Hi 

Hi 

*Off 

On 

On 

On 

Off 

LOW 

AUTO 

VALVE 

FAN SPEED 

Lo 

Adjust setpoint as follows: 

more than 0.4°F ABOVE room temperature 

3.0°F down to 5.9°F BELOW room temperature 

0.4°F ABOVE to 2.9°F BELOW room temperature 

6.0°F or more BELOW room temperature 

Cold Pipe 

MED 

Lo 

Off *Off 

Lo 

Lo Med 

Lo Med 

Lo 

Hi Med 

HIGH 

*Off 

Hi 

Hi 

Hi 

Off 

On 

On 

On 

LOW 

AUTO 

VALVE 

FAN SPEED 

Med 

2PE Functions:

System with a single valve that supplies both hot and cold water and 
has an auxiliary electric strip heat for use when pipe is cold.
The cooling wire of the thermostat will be used to control the water 
valve for heat and cool.
The heat wire will operate auxiliary electric strip heat.

FUNCTION CHART 2PE 

Adjust setpoint as follows: 

6.0°F or more ABOVE room temperature 

3.0°F up to 5.9°F ABOVE room temperature 

0.4°F BELOW to 2.9°F ABOVE room temperature 

more than 0.4°F BELOW room temperature 

Hot Pipe 

MED 

Lo 

Hi Med 

Lo 

Med Med 

Lo Med 

Lo 

Off Med 

HIGH 

Hi 

Hi 

Hi 

Hi 

On 

On 

On 

Off 

LOW 

AUTO 

VALVE 

FAN SPEED 

Lo 

AUX HT 

SYSTEM 

Adjust setpoint as follows: 

6.0°F or more ABOVE room temperature 

3.0°F up to 5.9°F ABOVE room temperature 

1.9°F BELOW to 0.4°F BELOW room temperature 

2.0°F BELOW room temperature (cool threshold) 

Cold Pipe, Active auxiliary heat 

MED 

Lo 

Hi Med 

Lo 

Med Med 

Lo Med 

Lo 

Lo Med 

HIGH 

Hi 

Hi 

Hi 

Hi 

On 

On 

Off 

Set 

Reset 

LOW 

AUTO 

VALVE 

FAN SPEED 

Off 

AUX HT 

SYSTEM 

0.4°F BELOW to 2.9°F ABOVE room temperature 

Lo Med Hi 

On 

Lo 

Adjust setpoint as follows: 

2.0°F ABOVE room temperature 

1.9°F ABOVE to 1.9°F BELOW room temperature 

Cold Pipe, Dynamic Dead Band 

MED 

Lo 

Lo Med 

Lo 

Off Med 

HIGH 

Hi 

Hi 

Set 

Off 

Off 

Set 

Off 

LOW 

AUTO 

VALVE 

FAN SPEED 

AUX HT 

SYSTEM 

2.0°F BELOW room temperature 

Lo Med Hi 

Lo 

Cooling Currently Active 

2.0°F ABOVE room temperature (heat threshold) 

1.9°F ABOVE to 0.4°F ABOVE room temperature 

3.0°F BELOW to 5.9°F BELOW room temperature 

6.0°F or more BELOW room temperature 

Cold Pipe, Active Cooling 

MED 

Lo 

Lo Med 

Lo 

Off Med 

Lo Med 

Lo 

Hi Med 

HIGH 

Hi 

Hi 

Hi 

Hi 

Set 

On 

On 

On 

Off 

Reset 

LOW 

AUTO 

VALVE 

FAN SPEED 

Med 

AUX HT 

SYSTEM 

0.4°F ABOVE to 2.9°F BELOW room temperature 

Lo Med Hi 

Lo 

 

SEN3 

SEN2 

REF 

+3V 

SB1 

SB2 

COM 

 

 

 

Отзывы: