Combi-Stat RTS8
Room Thermostat
Installation
instructions
RELEVANT EC DIRECTIVES:
2006/95/EC
Low Voltage Directive
2004/108/EC
Electromagnetic Compatibility
2011/65/EU
RoHS Directive
APPLIED STANDARDS:
EN60730-1, EN60730-2-9
Energy Class
I = 1% (According to EU 811/2013,
812/2013, 813/2013, 814/2013)
Telephone: +44 (0) 845 130 5522
Facsimile: +44 (0) 845 130 0622
Technical Helpline: +44 (0) 845 130 7722
Website: www.draytoncontrols.co.uk
Email: [email protected]
6490018-1 Iss D
0503
Drayton Controls reserve the right
to make changes without notice
and cannot accept liability for errors.
THERMOSTAT INTERCHANGE GUIDE
d
e
i
f
s
i
t
a
S
d
n
a
m
e
D
n
o
m
m
o
C
e
v
i
L
l
a
r
t
u
e
N
h
t
r
a
E
l
e
d
o
M
e
k
a
M
3
L
N
1
S
R
s
a
G
h
s
i
t
i
r
B
British Gas
RS2 (for 2 wire connectionwith loads of 0.1 to 0.6 A)
L
2
British Gas
RS2 (for 2 wire connection with loads 0.6 to 6A)
L
3
British Gas
RS2 (for 3 wire connection with loads under 2A)
N
L
3
2
3
1
L
N
4
S
R
s
a
G
h
s
i
t
i
r
B
Drayton
RTS7 and RTS8 (for 2 wire connection with loads of 0.1 to 0.6 A)
L
2
Drayton
RTS7 and RTS8 (for 2 wire connection with loads 0.6 to 6A)
L
3
Drayton
RTS7 and RTS8 (for 3 wire connection with loads under 2A)
N
L
3
3
L
N
1
S
T
R
n
o
t
y
a
r
D
3
L
N
2
S
T
R
n
o
t
y
a
r
D
2
3
1
L
N
4
S
T
R
n
o
t
y
a
r
D
2
1
4
E
2
4
1
S
T
e
l
y
t
s
e
f
i
L
L
C
A
2
3
1
5
0
5
3
A
T
e
l
y
t
s
e
f
i
L
L
C
A
Drayton (old version)
3
2
1
4
T
R
Drayton (old version)
4
E
T
R
1
2
3
3
2
1
4
0
3
2
T
M
R
ll
a
d
n
a
R
s
s
o
f
n
a
D
4
3
L
N
0
3
2
T
E
R
ll
a
d
n
a
R
s
s
o
f
n
a
D
Danfoss Randall
RT1
1
3
2
2
1
4
3
D
R
l
l
a
d
n
a
R
s
s
o
f
n
a
D
2
1
4
A
3
D
R
l
l
a
d
n
a
R
s
s
o
f
n
a
D
2
1
3
N
E
C
T
R
l
l
a
d
n
a
R
s
s
o
f
n
a
D
2
1
3
N
E
M
T
R
l
l
a
d
n
a
R
s
s
o
f
n
a
D
2
1
3
N
E
R
S
R
l
l
a
d
n
a
R
s
s
o
f
n
a
D
2
1
3
N
4
0
5
R
l
l
a
d
n
a
R
s
s
o
f
n
a
D
Honeywell
T4360B
1
3
4
3
1
2
B
0
6
0
6
T
l
l
e
w
y
e
n
o
H
4
3
1
2
B
1
6
0
6
T
l
l
e
w
y
e
n
o
H
4
3
1
2
B
3
6
0
6
T
l
l
e
w
y
e
n
o
H
4
3
1
2
B
0
6
3
6
T
l
l
e
w
y
e
n
o
H
2
1
4
E
1
T
R
H
n
n
a
m
t
s
r
o
H
Horstmann
Centuarstat
1
2
3
3
2
1
E
1
D
A
R
r
y
G
&
s
i
d
n
a
L
Landis & Gyr
RAD 1N
1
2
3
Landis & Gyr
RAD 1EM
1
2
3
H
L
N
1
T
R
P
n
o
t
r
e
t
t
o
P
H
L
T
N
2
T
R
P
n
o
t
r
e
t
t
o
P
H
L
T
N
T
S
0
0
1
T
R
P
n
o
t
r
e
t
t
o
P
C
H
L
T
N
T
D
0
0
1
T
R
P
n
o
t
r
e
t
t
o
P
1
3
4
E
2
2
2
2
X
L
T
c
i
v
n
u
S
1
3
/
L
N
E
9
5
2
2
X
L
T
c
i
v
n
u
S
2
1
3
N
E
6
5
3
2
X
L
T
c
i
v
n
u
S
1
3
4
E
4
5
6
2
X
L
T
c
i
v
n
u
S
2
1
3
4
E
2
5
8
2
X
L
T
c
i
v
n
u
S
2
3
1
E
0
5
3
A
T
c
a
p
o
S
2
3
1
4
E
1
5
3
A
T
c
a
p
o
S
2
3
1
5
2
T
R
S
r
e
t
s
a
m
h
c
t
i
w
S
2
1
4
E
S
S
r
e
w
o
T
NOTE: British Gas RS2 & Drayton RTS7 details are for guide use only. ALWAYS follow above instructions.
TECHNICAL DATA
Electrical supply
24V-230V AC/DC
Double insulated no earth
required
Temperature range
10°C to 30°C
Switch type
SPST 6(2)A
See Figs 5 to 7 for supply
voltage and maximum loads
which are dependant on
wiring configuration used
Temperature sensor Bi metallic
Continued from overleaf
Combi-Stat boiler compatibilty information
Make
Model
Alpha
240
2 wire
Ocean 80
3 wire
Ariston
Genus 27
2 wire
Euro Combi 27
2 wire
Biasi
Prisma
2 wire
Riva
3 wire
Chaffoteaux Britony Combi 80
3 wire
Celtic FF
3 wire
Ferrolli
Domina 80
2 wire
Modena 80
2 wire
Halstead
Finest
2 wire
Finest Gold
2 wire
Radiant
RSF 24
2 wire
Ravenheat
RSF 820/20
2 wire
CSI 85 Condensing 2 wire
Saunier
Duval 623 Combi
2 wire
Myson
Midas BF
2 wire
Elm
Le Blanc
2 wire
Combi
Stat