13
N.B.
This appliance must be installed according to the instructions on the unit’s certification label.
2.3
CLEARANCES TO COMBUSTIBLE MATERIALS
2.3.1 CLEARANCES TO COMBUSTIBLE MATERIALS FOR THE UNIT
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN THE INSTALLATION OF THIS UNIT.
EVEN IF THE REQUIRED CLEARANCES FOR MAINTENANCE PURPOSES ARE 24’’, WE RECOMMEND 30’’ IN
ORDER TO FACILITATE THE ACCESS TO THE FURNACE.
2.3.2 CLEARANCES TO COMBUSTIBLE MATERIALS FOR THE CHIMNEY
NOTE: REFER TO THE MANUFACTURER’S OWNER’S MANUAL FOR CHIMNEY CLEARANCES.
2.3.3 CLEARANCES TO COMBUSTIBLE MATERIALS FOR THE PLENUM
The plenums installed to the furnaces must be constructed of metal in accordance with NFPA 90B, 2-1.3. The
plenum can be passed through the side wall with 2 inches of clearances around the plenum.
Hot air plenum minimal height.
LEFT WALL
60"
24"
2"
STATIC PRESSURE CHECK
POINT MIN 0.20 W.C.
SEE NOTE*
CEILING
PLENUM
CEILING
2'
SEE
FIGURE
BELOW
8" MIN
A or B
Содержание CADDY ALTERNA
Страница 11: ...11 A B C Step 2 Remove the screws around the blower assembly...
Страница 49: ...49 6 GENERAL WIRING DIAGRAM...
Страница 50: ...50...
Страница 51: ...51...
Страница 52: ...52 7 WIRING DIAGRAM WITH OPTIONAL ELECTRICAL ELEMENT CADDY ALTERNA PELLET ELECTRIC COMBINATION FURNACE...