53
8.
CADDY ALTERNA TECHNICAL DATA
CADDY
ALTERNA
"B"
"C"
"F"
"D"
"A"
"H"
"E"
"G"
A
56 ¼”
B
26 ¼”
C
47”
D
21 ¼”
E
22”
F
22”
G
29 ½”
H
16 ¼”
FLUE
PIPE
4”
WEIGHT
500 lbs
8.1 GENERAL
TECHNICAL
DATA
MODEL DIRECT
DRIVE
THEORETICAL
FLOW
TEMP
VAR.
BTU INPUT
STATIC PRESSURE
FILTER
FAN MOTOR SPEED
(CFM)
(
O
F)
(PELLET)
MIN.
MAX.
(1)
IN.W.C.
CADDY ALTERNA
G-10
1/2HP 4
1650
110 120,000 0,2
0,5
16” x 20” X 1”
8.2
TECHNICAL DATA – ELECTRICAL ELEMENT
MODEL
OUTPUT
(CFM)
TEMP. VAR.
(
O
F)
BTU/HR
AMPS
TOTAL
BREAKER
REQUIRED
FEEDER
GAUGE
VOLTAGE
SINGLE PHASE
ELEMENTS
QTY
15 kW
1650
65
51,180
65
100 amps
4
120/240
3 x 5 kW
20 kW
1650
75
68,240
85
125 amps
3
120/240
4 x 5 kW
PELLET 1650
110
115,000 6
15
amps
14
120
N/A
8.3
TECHNICAL DATA – OTHER COMPONENTS
Igniter: lda00068, 500 Watts, 120 volts
Fuses: Midget 30 amps Time-Delay (Littelfuse)