background image

Upflow/Horizontal — Downflow/Horizontal, Gas-Fired Furnaces, 

“Fan Assisted Combustion System”

ALL phases of this installation must comply with

NATIONAL, STATE AND LOCAL CODES

IMPORTANT — This Document is customer property and is to

remain with this unit. Please return to service

information pack upon completion of work.

A341789P12

INSTALLER’S GUIDE

Upflow/ Horizontal*

Downflow/ Horizontal*

For VENT SIZING INFORMATION see:

USA —

National Fuel Gas Code  ANSI Z223.1/ NFPA 54 (latest version)

CANADA—

Natural Gas Installation Code 

CAN/ CGA-B149.1 (latest version)

Propane Installation Code  CAN/ CGA-B149.2 (latest version)

*Horizontal Conversion for these furnaces may be left 

or right side rotation.

18-CD34D1-5-EN

OPTIONAL ACCESSORIES

Model Number

Description

BAYBASE205

Downflow subbase for downflow models 

only

BAYFLTR200

External side filter rack

BAYFLTR203

Filter kit horizontal for 17.5" cabinet

BAYFLTR204

Filter kit horizontal for 21" cabinet

BAYFLTR205

Filter kit horizontal for 24.5" cabinet

BAYFLTR317

Cleanable filter for 17.5" cabinet upflow 

only

BAYFLTR321

Cleanable filter for 21" cabinet upflow 

only

BAYFLTR324

Cleanable filter for 24.5" cabinet upflow 

only

BAYLPKT210B

Propane conversion kit

BAYLPSS210B

LP kit with stainless steel burners

BAYRACK960A

Internals filter rack kit for upflow models

BAYVENT800B

Masonry chimney vent kit for upflow only

KIT09224

Filter clip kit

BAYBRCKFLT10

Downflow bracket kit

FLR01185

Filter for 14-1/2" cabinet downflow only

FLR01186

Filter for 17-1/2", 21", 24-1/2" cabinet 

downflow only

M801P040AU24AA
M801P060AU24AA
M801P060AU36AA
M801P080BU36AA
M801P080BU48AA 

M801P100BU36AA
M801P100CU48AA
M801P100CU60AA
M801P120DU60AA
M801P140DU60AA

M801P060AD24AA
M801P060AD36AA
M801P080BD45AA
M801P100CD48AA

M801P100CD60AA
M801P120DD60AA
M801P140DD60AA

Содержание M801P040AU24AA

Страница 1: ...els only BAYFLTR200 External side filter rack BAYFLTR203 Filter kit horizontal for 17 5 cabinet BAYFLTR204 Filter kit horizontal for 21 cabinet BAYFLTR205 Filter kit horizontal for 24 5 cabinet BAYFLT...

Страница 2: ...d components upon substantial completion of the construction process and verify furnace operating conditions including ignition input rate temperature rise and venting according to the manufacturer s...

Страница 3: ...and bathroom exhausts so they are operating at maximum speed Do not operate a summer exhaust fan 5 Follow the lighting instructions Place the appliance be ing inspected into operation Adjust the therm...

Страница 4: ...above the floor and the furnace must be located or protected to avoid physical damage from vehicles CAUTION To prevent shortening its service life the furnace should not be used as a Construction Heat...

Страница 5: ...E DRAWINGS UPFLOW HORIZONTAL For the M801P Series Furnaces MODEL DIM A DIM B DIM C DIM D M801P040AU24AA M801P060AU24AA M801P060AU36AA 14 1 2 9 5 8 13 1 4 13 M801P080BU36AA M801P080BU48AA M801P100BU36A...

Страница 6: ...NECTION 1 5 8 HOLE WITH PLUG 1 5 8 HOLE WITH PLUG 3 7 8 HOLE WITH PLUG ELECTRICAL CONNECTION ALTERNATE MODEL DIM A DIM B DIM C DIM D M801P060AD24AA M801P060AD36AA 14 1 2 9 5 8 13 1 4 13 M801P080BD45AA...

Страница 7: ...with downflow furnaces for installation to stabilize and secure the furnace and cased coil in the horizontal position See Figure 4 IMPORTANT The cased coil must be placed downstream of the furnace In...

Страница 8: ...ance with latest edition of Section 5 3 Air for Combustion and Ventilation of the National Fuel Gas Code ANSI Z223 1 or Sections 7 2 7 3 or 7 4 of CAN CGA B149 Installation Codes and applicable provis...

Страница 9: ...installations will require use of OUT DOOR AIR for combustion due to chemical exposures Commercial buildings Buildings with indoor pools Furnaces installed in commercial laundry rooms Furnaces install...

Страница 10: ...taining the furnace the return air shall also be handled by a duct s sealed to the furnace and terminating outside the space containing the furnace Minimum return air air entering temperature for the...

Страница 11: ...rnaceisaccessible itisrecommended that both supply and return air plenums are removable 8 When replacing a furnace old duct work should be cleaned out Thin cloths should be placed over the registers a...

Страница 12: ...end tab in the slot Replace screws Remove brackets Screw locations Flanges upward TABLE 6 CABINET WIDTH RETURN DUCT WIDTH FILTER ACCESS OPENING DIMENSION A FILTER ACCESS OPENING DIMENSION B 14 1 2 13...

Страница 13: ...ructions with the kit must be followed WARNING CARBON MONOXIDE POISONING HAZARD Failure to follow the steps outlined below for each appliance connected to the venting system being placed into operatio...

Страница 14: ...nder positive pressure 11 Horizontal pipe runs must be supported by hangers straps or other suitable material in intervals at a minimum of every 3 feet of pipe 12 A furnace shall not be connected to a...

Страница 15: ...GRAM FOR 1 STAGE FURNACE 1 STAGE HEATING 1 STAGE COOLING USING A 1 STAGE HEATING 1 STAGE COOLING THERMOSTAT OUTDOOR SECTION WITHOUT TRANSFORMER SEE NOTE 5 From drawing B342026 Rv 0 FURNACE SEE NOTE 6...

Страница 16: ...l Electrical Code ANSI NFPA 70 latest edition or Canadian Electrical Code CSA C22 1 if an external electrical source is utilized All field supplied wiring must conform with the temperature limitation...

Страница 17: ...ECK 1 Make sure all gas appliances are off except furnace 2 Clock the gas meter with the furnace operating determine the dial rating of the meter for one revolution 3 Match the Sec column in the gas f...

Страница 18: ...screw 9 Using a leak detection solution or soap suds check for leaks at the pressure outlet boss and pressure tap test screw 10 Turn on system power and check operation of unit CAUTION Replace and or...

Страница 19: ...rate and temperature rise should be checked again after changing orifices to confirm the proper rate for the altitude Installations above 4 000 feet may require a pressure switch change If required us...

Страница 20: ...es to make sure they are within the ranges specified on the furnace rating nameplate If the airflow needs to be increased or decreased see the wiring diagram for information on changing the speed of t...

Страница 21: ...or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not t...

Страница 22: ...R S GUIDE The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice Ingersoll Rand 11819 N Pennsylva...

Отзывы: