Programming the PowerWedge 10
13
PowerWedge
®
10
Predefined Defaults
The PowerWedge 10 has the following three sets of default parameters:
•
Predefined Default 0 (D0)
turns every on/off parameter off and sets all
minimum and maximum lengths to zero (00). Menu programming
remains enabled. This default set makes it easy for you to start with
everything off and then enable only the bar code symbologies and
parameters you wish to use. This can prevent unwanted data entry
to your applications.
•
Predefined Default 1 (D1)
turns every on/off parameter on and sets all
maximum lengths as high as possible. It also sets bar code and mag-
netic stripe preambles and postambles. This default set gives you the
best chance of reading an unknown bar code symbology, and it also
identifies the bar code type for you.
•
Predefined Default 2 (D2)
is the default set that was installed in the
decoder at the factory. This default set meets most users’ needs.
You can reset your PowerWedge 10 to one of the predefined default sets by
scanning one of the following bar codes:
NOTE
The host device setting (C0) is not affected by the predefined default sets.
D0
*$+$-D0EE*
D1
*$+$-D1EE*
D2
*$+$-D2EE*