Programming the PowerWedge 10
21
PowerWedge
®
10
Figure 7. On-screen programming options for Codabar, Ames, MSI, and Code 93
Notice that the parameters in this list are also identified by numbers
and letters. The value following the equals sign (=) in each line is the
current setting for that parameter (0 means off, and 1 means on).
The last line is the input prompt.
5. Type the I.D. of the parameter whose setting you want to change,
and press
Enter
. A prompt will display the valid settings or range of
settings for the parameter, as shown in the following example:
ENABLE CODABAR/AMES (0¦1):
6. Type the setting you want to use, and press
Enter
. The list of options
will be redisplayed to verify the change you made.
CODABAR/Ames
0 ENABLE=1
1 MIN LENGTH=04
2 MAX LENGTH=20
3 TRANSMIT START/STOP=0
4 CODABAR TO CLSI CONVERSION=0
5 INTERCHARACTER GAP CHECK=0
MSI
6 ENABLE=0
7 MIN LENGTH=04
8 MAX LENGTH=10
9 2ND CHECKSUM REQUIRED=0
A 2ND CHECKSUM MOD 11=0
B TRANSMIT CHECKSUM=0
CODE93
C ENABLE=1
D MIN LENGTH=02
E MAX LENGTH=20
(0-B):
NOTE
To return to the previous menu level, press the
Backspace
key on your key-
board.