Fibre to SAS/SATA Disk Array
66
User Manual
3.5 Powering Off
IMPORTANT: When powering off the Disk Array, turn off first the
Main Switch in the front panel and allow at least 3 minutes for the
subsystem to shutdown properly. During this time, each disk slot
starting from slot #1 until slot #64 will be powered down. The
main switch button in the front panel will flash blue.
When Disk Array has totally powered down, turn off the switches
of the 2 Power Supply Fan Modules at the rear. The main switch
button in the front panel will still flash blue until the power cords
are pulled out from the sockets.