Fibre to SAS/SATA Disk Array
User Manual
143
The Hardware Monitor Information provides information about controller, enclosure 1 and
enclosure 2, such as the temperature, fan speed, power supply status and voltage levels.
All items are also unchangeable. When the threshold values are surpassed, warning
messages will be indicated through the LCD, LED and alarm buzzer.
Item
Warning Condition
CPU Temperature
> 90 Celsius
Controller Board Temperature
> 80 Celsius
HDD Temperature
> 65 Celsius
Fan Speed
< 700 RPM
Power 12V
< 10.5V or > 13.5V
Power 5V
< 4.7V or > 5.4V
Power 3.3V
< 3.0V or > 3.6V
DDR-II +1.8V
< 1.62V or > 1.98V
CPU +1.8V
< 1.62V or > 1.98V
CPU +1.2V
< 1.08V or > 1.32V
CPU +1.0V
< 0.9V or > 1.1V
DDR-II +0.9V
< 0.81V or > 0.99V
RTC 3.0V
< 2.7V
Содержание EP-4643S2D2-F8S6
Страница 1: ...Fibre to SAS SATA RAID Subsystem User Manual Revision 1 1...
Страница 47: ...Fibre to SAS SATA Disk Array User Manual 47 3 Place the drive carefully in the disk slot...
Страница 74: ...Fibre to SAS SATA Disk Array 74 User Manual...
Страница 75: ...Fibre to SAS SATA Disk Array User Manual 75...
Страница 76: ...Fibre to SAS SATA Disk Array 76 User Manual...
Страница 77: ...Fibre to SAS SATA Disk Array User Manual 77...
Страница 78: ...Fibre to SAS SATA Disk Array 78 User Manual...
Страница 79: ...Fibre to SAS SATA Disk Array User Manual 79...
Страница 88: ...Fibre to SAS SATA Disk Array 88 User Manual NOTE Cannot expand Raid Set when contains Raid30 50 60 volume...
Страница 140: ...Fibre to SAS SATA Disk Array 140 User Manual...
Страница 150: ...Fibre to SAS SATA Disk Array 150 User Manual 12 Select Yes again to confirm The RAID controller will restart...