3.3 Preparing the Disk Array
1.
Install the disk drives, if not yet installed. Refer to Section 2.6 Disk Drive
Installation for detailed information.
2.
Attach network cable to the R-Link port. Connect the other end to your network
hub or switch.
3.
Connect one end of Fibre optic cable to the Host Channel port of the subsystem
and the other end to the Fibre HBA on the Host system or to the FC switch.
NOTE: If a JBOD subsystem will be connected to the Disk Array,
connect the SAS cable from the SAS Expansion Port of Disk Array
to the SAS In Port of JBOD subsystem.
3.4 Powering On
1.
Plug in all the power cords into the AC Power Input Socket located at the PSFM.
The main switch button in the front panel will flash blue indicating that the power
cords are inserted.
NOTE: The subsystem is equipped with redundant, full range
power supplies with PFC (power factor correction). The system
will automatically select voltage.
NOTE: The PSFM has a 5V standby DC voltage. When the power
cord(s) is/are connected to the AC Power Input Socket, after 1
second, all Activity LEDs will flash once. When the power cord(s)
is/are disconnected from AC Power Input Socket, after 3 seconds,
all Activity LEDs will flash twice.
2.
Turn on each Power On/Off Switch of the PSFM. The main switch button in the
front panel will still flashing blue.
NOTE: When the power cord connected from main power source is
inserted to the AC Power Input Socket, the Power Status LED
becomes
RED
. When the switch of the PSFM is turned on, the LED
still shows
RED
. After the main switch in front panel is turned on,
the LED turns
GREEN
, which means it is functioning normally.
Содержание EP-4643S2D2-F8S6
Страница 1: ...Fibre to SAS SATA RAID Subsystem User Manual Revision 1 1...
Страница 47: ...Fibre to SAS SATA Disk Array User Manual 47 3 Place the drive carefully in the disk slot...
Страница 74: ...Fibre to SAS SATA Disk Array 74 User Manual...
Страница 75: ...Fibre to SAS SATA Disk Array User Manual 75...
Страница 76: ...Fibre to SAS SATA Disk Array 76 User Manual...
Страница 77: ...Fibre to SAS SATA Disk Array User Manual 77...
Страница 78: ...Fibre to SAS SATA Disk Array 78 User Manual...
Страница 79: ...Fibre to SAS SATA Disk Array User Manual 79...
Страница 88: ...Fibre to SAS SATA Disk Array 88 User Manual NOTE Cannot expand Raid Set when contains Raid30 50 60 volume...
Страница 140: ...Fibre to SAS SATA Disk Array 140 User Manual...
Страница 150: ...Fibre to SAS SATA Disk Array 150 User Manual 12 Select Yes again to confirm The RAID controller will restart...