12.0 Options (Menu 2)
12.1 General Options (Menu 2, 1)
The General Options set options that relate to the general operation of the Protégé® EliteSuite®
Eclipse LED Keypad.
Step 1
To enter the General Options menu enter the following key press sequence:
, 2, 1
The currently assigned values will be displayed using the number LED’s.
Step 2
To toggle options press the keys 1 to 8, and the corresponding number LED will be lit when that
option is enabled.
Step 3
Pressing the
ENTER
key ( ) will save the options. Pressing the
MENU
key ( ) will abort the
operation without saving any changes.
The available options are:
Option 1 - Zone Type Option 1
If Duplex Zone (Option 2) is not enabled then Option 1 will set the Zone Input Configuration (EOL
or NO EOL). EOL requires the use of 2x 1k resistors to provide, Short, Alarm, Closed and Tamper
monitoring. NO EOL provides alarm and closed monitoring.
• Enabled, EOL resistors are used (2R Mode) (2 zones).
• Disabled, NO EOL resistors are used (2 zones).
Option 2 - Duplex Zone Operation
If Option 2 is set Option 1 does not have any function. When Option 2 is set the zones will use a
1k and 2k4 resistor and provide monitoring for 2 zones.
• Enabled, Duplex Zone Mode (4 zones).
• Disabled, Option 1 sets the zone configuration.
Option 3 - Beep On Trouble Condition
• Enabled, the beeper will emit 2 beeps every minute if a trouble condition is present, to silence
the trouble beep, view the trouble condition.
• Disabled, no trouble beep will be generated.
23