background image

4

BB

B

B

50 mm

345 mm LEADER 3 TI

445 mm LEADER 4 TI

545 mm LEADER 5 TI

50 mm

445 mm

Fig. 3

Fig. 4

Fig. 5

Fig. 6

Fig. 7

Fig. 2

 

3.3  ESTABLISHING RH AND LH OPERATOR 

A RH motor 

and a 

LH motor 

are supplied with the kit. 

Ensure you are mounting the correct handed motor to the 

leaf (see picture 3, inner view). 

Make sure there are mechanical ground stops in opening 

and closing (see picture 

B

)

.

LEADER TI

 

Gate in closing position

 - inox pipe maximum extension:

Leader 3 = 345 mm

Leader 4 = 445 mm

Leader 5 = 545 mm

Gate in opening position

 - inox pipe minimum extension 50 mm

(see picture 4).

LEADER TA 

 

Gate in closing position

: minimum distance 50 mm.

Gate in opening position

: maximum distance 450 mm. 

(see picture 5).

3.4

  

FASTENING THE GEARMOTOR

3.4.1 Vertical positioning quota

a)

  If the gate is sturdy you can fit the gearmotor wherever 

it goes, at any height from ground.

b)

  If the gate is particularly light fit the gearmotor as close 

as possible to gate centerline.

3.4.2 Horizontal positioning quota
Gate leaf hinged in the center of the pillar 

(see picture 6).

Gate leaf hinged on the corner of the pillar

(see picture 7).

Best of performance is obtained respecting 

A

 and 

B

 

dimensions, see picture 8 (opening angle 90°).

  Cut off the power before starting wiring.

•  Make  sure  you  have  set  up  a  suitable  dual-pole  cut  off 

device ( 3 mm wires) along the power supply. 

•  Make sure you have suitable tubing and conduits for the 

electrical cables: connect the motors, control panel and 

accessories using separated currugated tubes, in order to 

prevent interferences that may result in bad operation. 

•  Fit the power cable keeping a curve as shown in picture 2, 

in order to avoid water blackflow inside the operator.  

•  All opening commands and safety devices must be free of 

tension (dry contact).

LEFT HAND 

operator

RIGHT HAND

operator

= Mechanical ground stops

opening position

closing position

Содержание LEADER 3

Страница 1: ...01_17 LEADER Gearmotor for swing gates INSTALLATION MANUAL...

Страница 2: ......

Страница 3: ...3 2 Wiring pag 03 3 2 1 Standard installation 3 2 2 Cable types and minimum thicknesses 3 3 Establishing RH and LH operator pag 04 3 4 Fastening the gearmotor pag 04 3 4 1 Vertical positioning quota 3...

Страница 4: ...24 4 TA Is built to be integrated into a machine or to be assembled with other machinery to crate a machine under provisions of 2006 42 EC Machinery Directive with reference in particular to the follo...

Страница 5: ...0 kg 2 0 m 2 5 m 3 0 m 2 0 m 2 75 m 3 50 m 80 80 80 40 40 40 LEADER TI LEADER TA Leader 4 TA Leader 4 TA 24 Leader 4 TA 115 230V 50Hz 1 2 1 7A 280W 8 F 150 C 2800 N 44 1400 rpm 110 deg 22 300 Kg 2 75...

Страница 6: ...manual release Any lawn watering devices will not wet the gearmotor from the bottom up The earth cable is properly connected Do not install onto gates on either an upward or downward slope i e that ar...

Страница 7: ...t any height from ground b If the gate is particularly light fit the gearmotor as close as possible to gate centerline 3 4 2 Horizontal positioning quota Gate leaf hinged in the center of the pillar s...

Страница 8: ...tor stroke Leader 3 TI C 300 mm Leader 4 TI C 400 mm Leader 5 TI C 500 mm If the ideal scenario of A and B is not applicable refer to the below table to determine the brackets position values are expr...

Страница 9: ...minimum distance of 30 35 mm from the post edge in order to avoid damages see picture 11 Rear brackets T1 are provided LH and RH to match to the according LH and RH motor see picture 12 When fixing th...

Страница 10: ...an proceed to manual operation To return to automatic operation invert the procedure RH OPERATOR Insert the key and turn 90 counterclockwise picture 17 Pull the release handle outwards to unlock the m...

Страница 11: ...8 24V 230V 18 22 B 3 9 13 19 23 24 39 29 30 26 34 35 31 33 3 3 40 40 40 40 43 44 44 43 1 4 5 6 7 15 16 38 37 17 36 32 22 A LEADER TI...

Страница 12: ...12 15 16 11 23 24 39 29 10 20 3 3 40 40 40 40 43 44 38 37 44 43 17 36 8 21 14 24V 26 22 A LEADER TA Proteco S r l Via Neive 77 12050 CASTAGNITO CN ITALY Tel 39 0173 210111 Fax 39 0173 210199 info prot...

Отзывы: