
CAUTION!
Warning of feed chemical spraying around
Feed chemical can spray out of the hydraulic compo‐
nents if they are manipulated or opened due to pressure
in the liquid end and adjacent parts of the system.
–
Disconnect the pump from the mains power supply
and ensure that it cannot be switched on again by
unauthorised persons.
–
Depressurise the system before commencing any
work on hydraulic parts.
WARNING!
Warning of eye injuries
When opening the relief valve, a spring under high ten‐
sion can jump out.
–
Wear protective glasses.
CAUTION!
Danger of damage to the device
The device can be damaged by incorrect and improper
storage and transport.
–
Take into account the information in the "Storage,
Transport and Unpacking" chapter if the system is
decommissioned for a temporary period.
1.
Disconnect the pump from the mains/power supply.
2.
Depressurise and bleed the hydraulic system around the pump.
3.
Drain the liquid end by turning the pump upside down and allowing
the feed chemical to run out.
4.
Flush the liquid end with a suitable medium - observe the material
safety data sheet! Flush the dosing head thoroughly when using
hazardous feed chemicals!
5.
Possible additional work - see chapter "Storage, Transport and
Unpacking".
Also drain the gear oil - refer to the chapter entitled "Maintenance".
CAUTION!
Environmental hazard due to incorrect disposal
–
Note the local guidelines currently applicable in your
country, particularly in regard to electronic waste!
(Temporary) decommissioning
Final decommissioning
Disposal
Decommissioning
84
Содержание Sigma/ 2 Control S2Cb
Страница 63: ...In the LANGUAGE menu you can select the desired operating lan guage Setting 63...
Страница 99: ...99...