A/C Humidity Control
(NT150e/h and NT160e/h only)
Select a relative humidity value from 10% to 90%. When the
measured RH rises above a preset threshold, the HVAC cooling
cycle is initiated. The cycle continues until the humidity level
falls 5% below the trigger level or until a heat setpoint is
encountered. When a heat setpoint is encountered, the HVAC
heating cycle is invoked. After the heat setpoint has been
satisfied, the HVAC cooling cycle (to satisfy humidity
requirements) is delayed for 5 minutes. Humidity control is
intended for moderate moisture control. High humidity
environments should also include secondary dehumidification
equipment.
Disable
– This feature is disabled and the A/C system may
not be used to reduce humidity.
10% – 90%
– Humidity threshold expressed in 5%
increments.