The appliances must be positioned in rooms which have
suitable system for discharging the products of combustion;
such a system must comply with installation instructions.
O
ur appliances are classified (see table 2 technical specifica-
tions chart) as:
-
type “
A
” gas appliances:
-
N
ot designed for connection to a line for discharge of the
products of combustion.
-
These appliances must discharge the products of com-
bustion into appropriate hoods, or similar devices, con-
nected to a flue of proven efficiency, or may be con-
nected directly with an outdoor vent.
-
I
f such an arrangement is not possible, the unit may be
connected to an air exhaust system which leads directly
outdoors, having capacity which corresponds to require-
ments. (
S
ee table 2).
E
lectrical c
o
nnecti
o
n
Before connecting the appliance to the mains, check that:
- The mains voltage corresponds to the values on the rat-
ing plate;
- The appliance is properly earthed;
- The cable is suitable for the power input.
I
n addition a tripping device with a contact cutoff of at least
3 mm must be placed between the appliance and the mains
socket so that omnipolar disconnection is possible.
S
afety
contactors, for example, may be used for this purpose.
The omnipolar switch must be near the appliance and easily
accessible.
The power cable must be approved and have a suitable
cross section for the appliance.
I
t should be at least the type
H
07
RN
-
F
.
T
he gr
o
un
d
yell
o
w-green cable must n
o
t be interrupte
d.
E
quip
o
tential
The appliance must be connected to an equipotential
system.
The relative terminal can be found at the rear of the appli-
ance near the cable inlet, marked by a label.
COMMISSIONING
THE
APPLIANCE
B
ef
o
re c
o
mmissi
o
ning the appliance
Before commissioning the appliance, remove the protective
wrapping. Thoroughly clean the work-surface and the out-
side of the appliance using lukewarm water and detergent.
S
tart-up
Before starting the appliance up, check that its specifications
(category and type of gas used) match those of the family
and group of the gas available locally.
I
f not, adapt the appliance to the gas family or group
required (see paragraph “
R
unning the appliance on other
types of gas”).
A
ttention: to ensure proper operation of teh
T
C
(triple crown) burners and their covers, they must be
postioned perfectly, see
F
ig. 1.1
A
void positions such as those shown in
F
ig. 1.2
T
esting the p
o
wer rating
U
se the nozzles for the nominal capacity on the appliance.
C
apacity can be of two types:
- nominal, as given on the data plate;
- reduced.
These nozzles are shown in the table on burners.
Tolerances within the following fields of input pressure:
- from 15 to 22.5 mbar for gases of the second family;
(methane)
- from 25 to 35 mbar for gases of the third family (butane
-propane).
The appliance will not work outside the above pressure
thresholds.
I
f you wish to check the nominal capacity further, you may
do so using a gas meter according to the so-called ”volu-
metric method”.
I
t is normally enough, however, simply to check that the
nozzles are functioning correctly.
C
hecking input pressure (Fig
.
2
)
I
nput pressure should be measured using a gauge (min.
resolution 0.1 mbar).
R
emove screw (
F
) from the pressure socket and connect the
gauge; after measuring, the screw should be retightened
absolutely airtight (
F
).
IMPORTANT
:
The pressure must be checked with all gas
equipment connected and operating.
Co
ntr
o
l
o
f p
o
wer with v
o
lumetric meth
od
U
sing a gas counter and a stopwatch, you can measure gas
consumtpion in a given unit of time. This value will be com-
pared with the value
E
and is calculated as follows:
E
=
Burner power
G
as heating power
The powers of the burner, both nominal nd reduced, calcu-
lated at the nominal pressure value, are obtained by referring
to table 1. The value of the heating power of the gas can be
requested from the local gas company.
Содержание G12F4H9 + FGP
Страница 30: ...ITALIANO 2 1 3 1 1 1 2 6 8 4 7 F 21 2 H 1 5 4 3 ...
Страница 31: ...ITALIANO 5 4 4 1 4 2 4 3 FG T FGP 5 1 5 2 36 ...
Страница 54: ...ITALIANO G9F4 FG1 G9F6 FG1 G9F8 2FG1 G9F8 2FE1 3 5 3 5 3 5 3 5 6 6 9 9 ...
Страница 55: ...ITALIANO G9F8 2FG G9F6 T 3 5 3 5 3 5 3 5 6 6 9 9 G9F8 2FE G9TPM ...
Страница 57: ...ITALIANO G9TP2FM G9TP2F FG G9F8P 2FG G9F6P T 9 9 9 9 9 9 9 9 ...
Страница 60: ...ITALIANO G9F4P FG1 G9F6P FG1 G9F8P 2FG1 9 9 9 9 9 9 9 9 ...
Страница 61: ...ITALIANO G12F4H9M G12F4H9 FGP G12F4P9 FGP G12F4P9M ...
Страница 62: ...ITALIANO SG9F2M SG9F2MP SG9F4MP SG9F4M ...
Страница 63: ...ITALIANO SG9F6M SG9F6MP SG9F4P FG SG9F4 FG ...
Страница 64: ...ITALIANO SG9F4 FE SG9F6 FG SG9F6 FE SG9F6P FG ...
Страница 65: ...ITALIANO SG9F6 T SG9F6P T SG9F8P 2FG SG9F8 2FG ...
Страница 66: ...ITALIANO SG9F8 2FE ...
Страница 302: ...Cod 31878500 E ...