INSTALLATION
Page 9
EN - English
DUPLEX/TRIPLEX PARALLEL
with multiple valve bypass (not included)
Picture 5
= inlet of water softener (untreated water)
= outlet of water softener (treated water)
= Service Valve
1.
Install the multiple valve bypass system.
2.
Screw the connection kit with nuts onto the in/out ports
on the control valve (
&
); make sure to install the
gasket seals. Tighten the nuts firmly by hand.
3.
Screw the Service Valve (
) onto the adaptor (
) at the
out port of the control valve; make sure to respect the
flow direction (see indication arrow on the bottom of
the Service Valve); use an appropriate sealant.
4.
Connect the IN valve of the bypass system to the
adaptor on the in port (
) of the control valve.
5.
Connect the OUT valve of the bypass system to the
Service Valve (
).
6.
Repeat steps 2-5 for all Simplex systems.
7.
Connect the mains water supply to the inlet of the
multiple valve bypass systems.
8.
Connect the application to the outlet of the multiple
valve bypass systems.
QUADPLEX PARALLEL (= 2 x DUPLEX)
with multiple valve bypass (not included)
Picture 6
DRAIN
We recommend the use of a stand pipe with air trap.
To prevent backflow from the sewerage system into the
water softener, always make sure to have an air gap
between the end of the drain hose and the sewerage
system itself; as a rule of thumb, the air gap should be
minimum 2x the diameter of the drain hose.
Always use separate drain hoses for the control valve(s)
(evacuation of rinse water) and the brine tank's
overflow(s).
Lay-out the drain hoses in such a way that pressure loss
is minimized; avoid kinks and unnecessary elevations.
Make sure that the sewerage system is suitable for the
rinse water flow rate of the water softener.
Picture 7
1.
Connect a 13 mm hose to the drain elbow of the control
valve (
); secure it by means of a clamp.
2.
Run the drain hose to the sewerage system and connect
it to the stand pipe assuring sufficient air gap. This drain
line operates under pressure, so it may be installed
higher than the water softener.
3.
Connect a 13 mm hose to the overflow elbow on the
brine tank; secure it by means of a clamp.
4.
Run the drain hose to the sewerage system and connect
it to the stand pipe assuring sufficient air gap. This drain
line does NOT operate under pressure, so it may NOT be
installed higher than the water softener.
5.
For Duplex/Triplex
: repeat steps 1-4 for all Simplex
systems.
ELECTRICAL
Picture 8
1.
Plug the transformers output lead into the socket on the
water softeners power cord; secure it by means of the
TwistLock clamp.
2.
Plug the transformer into an electrical outlet.
SERVICE VALVES
Picture 9
1.
For Duplex/Triplex Parallel
: plug the DIN plug on the
connection cable of the Service Valve into the DIN socket
at the back of the electronic timer head of the respective
control valve (
).
INTERCONNECT CABLE
Picture 10
1.
For Duplex Alternating
: connect the control valves to
each other by means of the InterConnect cable; simply
plug the DIN plugs on the InterConnect cable in the DIN
sockets at the back of the electronic timer of each
control valve (
).
Содержание Water softener
Страница 2: ...EN English Page 3 FR Français Page 21 DE Deutsch Seite 39 NL Nederlands Pagina 57 PL Polski Strona 75 ...
Страница 93: ......
Страница 94: ......
Страница 95: ......
Страница 97: ... 2013 Aquion Inc PP ProFlow Rev2013 03 r 1 2 a 2 b 3 a 3 b ...
Страница 98: ... 2013 Aquion Inc PP ProFlow Rev2013 03 r 4 a 4 b 5 a 5 b r 5 c ...
Страница 99: ... 2013 Aquion Inc PP ProFlow Rev2013 03 6 7 a 7 b r 8 a 8 b ...
Страница 100: ... 2013 Aquion Inc PP ProFlow Rev2013 03 r 9 10 11 r 12 r 13 ...
Страница 101: ... 2013 Aquion Inc PP ProFlow Rev2013 03 14 15 a 15 b 15 c ...
Страница 102: ... 2013 Aquion Inc PP ProFlow Rev2013 03 ...
Страница 103: ... 2013 Aquion Inc PP ProFlow Rev2013 03 ...
Страница 104: ... 2013 Aquion Inc PP ProFlow Rev2013 03 ...