START-UP
EN - English
Page 10
PRESSURIZING
1.
Put the bypass system in 'bypass' position.
2.
Make sure the electronic controller(s) of the water
softener is (are) in service mode.
3.
Open the mains water supply.
4.
Open a cold treated water faucet nearby the water
softener and let the water run for a few minutes until all
air is purged and all foreign material that may have
resulted from the installation is washed out; close the
tap.
5.
Gently pressurize the water softener, by putting it into
service:
close the 'BYPASS' valve;
open the 'OUT' valve;
slowly open the 'IN' valve.
6.
After 2-3 minutes, open a cold treated water faucet
nearby the water softener and let the water run for a
few minutes until all air is purged from the installation
and the resin bed is rinsed (it is normal for the rinse
water to show some discoloration!); close the tap.
7.
Check the water softener and all hydraulic connections
for leaks.
8.
For:
Duplex/Triplex Parallel
: repeat steps 5-7 for all
Simplex systems.
Duplex Alternating
: repeat step 5, for the Slave
system.
Picture 11
= automatically operated = normally closed
= manually operated = constantly open
!
The Normally Closed Service Valve in the outlet
of each Simplex system will only be opened
when the respective system is put in service. To
manually open the Normally Closed Service
Valve(s) during pressurizing, simply turn the
white solenoid coil counter clockwise.
ELECTRONIC CONTROL PANEL
9.
Program the electronic controller.
10.
For Duplex/Triplex Parallel
: repeat step 9 for all Simplex
systems.
ADJUSTMENT RESIDUAL HARDNESS
ON CONTROL VALVE
Picture 12
11.
Adjust the residual hardness of the water that leaves the
softener, by means of the adjusting screw, incorporated
at the right side of the control valve:
to raise the residual hardness: turn the screw
counter clockwise;
to reduce the residual hardness: turn the screw
clockwise.
WITH FACTORY BYPASS (optional)
Picture 13
11.
Adjust the residual hardness of the water that leaves the
softener, by means of the adjusting screw, incorporated
in the 'outlet' valve of the factory bypass:
to raise the residual hardness: turn the screw
counter clockwise.
to reduce the residual hardness: turn the screw
clockwise.
INITIATE A REGENERATION
12.
Manually initiate a regeneration, by pressing the
scroll
button repeatedly until the display shows:
13.
Leave the water softener in this position; the count-
down timer will count down to 0 sec and start a
regeneration; to save time you may skip, or terminate
prematurely, the second cycle of the regeneration by
pressing the
scroll
button once, as soon as the display
indicates that the system is in the second regeneration
position.
14.
For:
Duplex/Triplex Parallel
: repeat steps 12-13 for all
Simplex systems, to put all Simplex systems into
regeneration simultaneously.
Duplex Alternating
: as soon as the Master system
has executed its regeneration, repeat steps 12-13 for
the Slave system.
INTERCONNECT CABLE(S)
Picture 10
15.
For Duplex/Triplex Parallel
: connect the control valves to
each other by means of the InterConnect cable(s); simply
plug the DIN plugs on the InterConnect cable(s) in the
DIN sockets at the back of the electronic timer of each
control valve (
).
Regen in 10 sec
Содержание Water softener
Страница 2: ...EN English Page 3 FR Français Page 21 DE Deutsch Seite 39 NL Nederlands Pagina 57 PL Polski Strona 75 ...
Страница 93: ......
Страница 94: ......
Страница 95: ......
Страница 97: ... 2013 Aquion Inc PP ProFlow Rev2013 03 r 1 2 a 2 b 3 a 3 b ...
Страница 98: ... 2013 Aquion Inc PP ProFlow Rev2013 03 r 4 a 4 b 5 a 5 b r 5 c ...
Страница 99: ... 2013 Aquion Inc PP ProFlow Rev2013 03 6 7 a 7 b r 8 a 8 b ...
Страница 100: ... 2013 Aquion Inc PP ProFlow Rev2013 03 r 9 10 11 r 12 r 13 ...
Страница 101: ... 2013 Aquion Inc PP ProFlow Rev2013 03 14 15 a 15 b 15 c ...
Страница 102: ... 2013 Aquion Inc PP ProFlow Rev2013 03 ...
Страница 103: ... 2013 Aquion Inc PP ProFlow Rev2013 03 ...
Страница 104: ... 2013 Aquion Inc PP ProFlow Rev2013 03 ...