ELECTRONIC CONTROL PANEL
Page 11
EN - English
Picture 14
symbol
button
function
SCROLL
to advance to the next
parameter
UP
to increase the value of the
parameter
DOWN
to decrease the value of the
parameter
POWER-UP
After power-up the display will show the installed software
version, f.e.:
After 5 seconds it will automatically revert back to the
service display.
POWER FAILURE
In the event of a power failure, the program will remain
stored in the NOVRAM® during an undefined period, while
an incorporated SuperCap (capacitor) will maintain the
correct time of day during a period of several hours;
consequently, in case of prolonged power failure, the time
of day might not be maintained; if this happens, the time of
day will be reset to 8:00 when the power supply is re-
established, while the indication will
flash
, indicating that
the time of day needs to be set.
When the power failure occurs during the execution of an
automatic regeneration, the control valve will remain in its
last position; when the power supply is re-established, the
control valve will return to the service position, stay there for
60 sec. and restart a complete regeneration from the
beginning.
TIMER FAILURE
In the event of a timer failure, the display will show the
message:
In such case, entering one of the programming levels can
possibly solve the problem. However if the problem persists,
professional service is required.
SERVICE MODE
In
service mode
the
display shows:
Simplex Tempo
: the time of day and the remaining
number of days:
Simplex Eco, Duplex/Triplex Eco Parallel
:
the time of
day and the remaining capacity:
Duplex Eco Alternating
:
which valve is in service and its
remaining capacity:
REGENERATION MODE
In
regeneration mode
the
display shows:
Simplex Tempo/Eco, Duplex/Triplex Eco Parallel
: the
total remaining regeneration time and remaining cycle
time:
Duplex
Eco
Alternating
:
the
total
remaining
regeneration time and remaining cycle time:
The control valve can be
reset to service mode
at any time
by pressing the
scroll
button, as such manually advancing
it through the regeneration cycles.
CHECKING THE FLOW METER
In case of water usage, the remaining capacity counter in the
service display will count back per unit, i.e. per litre. This way
the correct functioning of the water meter can be verified.
Service Required
EZRSDg EZ Rot0.8
Rgn:123 CycY:456
20:51 1000L -
20:51 4 DAY REM
8:00
1000L -
Valve 1 1000L
Rgn1:123CycY:456
Содержание Water softener
Страница 2: ...EN English Page 3 FR Français Page 21 DE Deutsch Seite 39 NL Nederlands Pagina 57 PL Polski Strona 75 ...
Страница 93: ......
Страница 94: ......
Страница 95: ......
Страница 97: ... 2013 Aquion Inc PP ProFlow Rev2013 03 r 1 2 a 2 b 3 a 3 b ...
Страница 98: ... 2013 Aquion Inc PP ProFlow Rev2013 03 r 4 a 4 b 5 a 5 b r 5 c ...
Страница 99: ... 2013 Aquion Inc PP ProFlow Rev2013 03 6 7 a 7 b r 8 a 8 b ...
Страница 100: ... 2013 Aquion Inc PP ProFlow Rev2013 03 r 9 10 11 r 12 r 13 ...
Страница 101: ... 2013 Aquion Inc PP ProFlow Rev2013 03 14 15 a 15 b 15 c ...
Страница 102: ... 2013 Aquion Inc PP ProFlow Rev2013 03 ...
Страница 103: ... 2013 Aquion Inc PP ProFlow Rev2013 03 ...
Страница 104: ... 2013 Aquion Inc PP ProFlow Rev2013 03 ...