ELECTRONIC CONTROL PANEL
EN - English
Page 16
DUPLEX/TRIPLEX ECO PARALLEL
:
Each Simplex system must be programmed individually;
the program does NOT necessarily have to be the same on
all Simplex systems, that make up a Duplex/Triplex system!
1.
Press the
scroll
button and hold it for 5 sec until the
display shows:
2.
Within 10 sec, press the
up
button; the display will
show:
Press the
up
or
down
button to set
the
hardness unit
.
Make sure to also adjust/convert the
exchange capacity!
3.
Press the
scroll
button again; the display will show:
Press the
up
or
down
button to set
the
exchange capacity per litre of resin
.
4.
Press the
scroll
button again; the display will show:
Press the
up
or
down
button to set
the volume
of resin
.
5.
Press the
scroll
button again; the display will show:
Press the
up
or
down
button to set
the number
of days between regenerations
.
6.
Press the
scroll
button again; the display will show:
Press the
up
or
down
button to set
the length
of the regeneration cycle
.
Press the
scroll
button again to advance to the
next regeneration cycle.
Cycle 1
Backwash
Cycle 2
Brine draw/slow rinse
Cycle 3
Fast rinse/refill
7.
Press the
scroll
button again; the display will show:
Press the
up
or
down
button to set
the type of
water meter sensor
.
8.
Press the
scroll
button again; the display will show:
Press the
up
or
down
button to set
the
regeneration mode
:
Immediate
: when the remaining capacity equals
0, an
immediate regeneration
is started.
Dlyd/Immd
: when the remaining capacity equals
the reserve capacity, a
delayed regeneration
at
the programmed time of regeneration is started;
however when the remaining capacity equals 0
before the programmed time of regeneration is
reached, an
immediate regeneration
is started.
Delayed
: when the remaining capacity equals
the reserve capacity, a
delayed regeneration
at
the programmed time of regeneration is started.
9.
Press the
scroll
button again; the display will show
(only when the regeneration mode is set to 'Delayed' or
'Dlyd/Immd'):
Press the
up
or
down
button to set
the time of
regeneration
.
10.
Press the
scroll
button again; the display will show
(only when the regeneration mode is set to 'Delayed' or
'Dlyd/Immd'):
Press the
up
or
down
button to set
the reserve
capacity
:
Variable
: the reserve capacity is calculated
automatically, based on the registered daily
water usage.
Fxd
: press the
scroll
button
again and press
the
up
or
down
button to set
the reserve
capacity to a fixed amount
.
11.
Press the
scroll
button again; the display will show:
Press the
up
or
down
button to save the
program into the NOVRAM® and exit the
programming level.
12.
Repeat steps 1-11 for all Simplex systems.
Cycle 1:
XX
min
System Check
HardUnit:
°f
Resin:
XXX
liters
ExCap:
5.5
°f M3/L
Override:
7
days
MTR:
SNAP SENSOR
Regen:Immediate
Rsrv
Variable
Regen @
2:00
Exit
Содержание Water softener
Страница 2: ...EN English Page 3 FR Français Page 21 DE Deutsch Seite 39 NL Nederlands Pagina 57 PL Polski Strona 75 ...
Страница 93: ......
Страница 94: ......
Страница 95: ......
Страница 97: ... 2013 Aquion Inc PP ProFlow Rev2013 03 r 1 2 a 2 b 3 a 3 b ...
Страница 98: ... 2013 Aquion Inc PP ProFlow Rev2013 03 r 4 a 4 b 5 a 5 b r 5 c ...
Страница 99: ... 2013 Aquion Inc PP ProFlow Rev2013 03 6 7 a 7 b r 8 a 8 b ...
Страница 100: ... 2013 Aquion Inc PP ProFlow Rev2013 03 r 9 10 11 r 12 r 13 ...
Страница 101: ... 2013 Aquion Inc PP ProFlow Rev2013 03 14 15 a 15 b 15 c ...
Страница 102: ... 2013 Aquion Inc PP ProFlow Rev2013 03 ...
Страница 103: ... 2013 Aquion Inc PP ProFlow Rev2013 03 ...
Страница 104: ... 2013 Aquion Inc PP ProFlow Rev2013 03 ...