M

odel Pro S 600T “TURBO” 

OPERATING IN REGULAR / EVAP MODE 

• 

Fill the reservoir to full level with baby oil provided. See back of 
unit for fill level

 

Do not over fill!

 

• 

Attach the Power Cables and Air/Smoke Hose to the 

Smoke 

Monster

®

 Turbo

 

• 

Attach power cables to a 

fully charged 

vehicle battery.

 

Do not 

attach to a battery charger!

 

• 

Machine will be powered up once power supply connected, and 

rocker  switch  is  in  the  “ON” 

position.  (rocker  switch  will  be 

illuminated)

 

• 

Once unit is powered up, the 2 LEDs will blink for a few seconds.

 

• 

After the led lights finish blinking, they will turn off, and the unit 
will be in EVAP air mode.

 

• 

By pushing the 

“Smoke

 

Mode”

 button, the LED light will be lit, and

 

unit is ready to start 5-minute smoke cycle. 

• 

Find the leaks and make necessary repairs.

 

OPERATING IN AIR LEAK DECAY MODE (both EVAP & TURBO) 

• 

Switch unit back to “Air Mode” and start pressurizing the

 vehicle

 

• 

Once vehicle is 

pressurized, turn the rocker switch to the “OFF” 

position and see if the pressure holds then the leak has been 
repaired. If the gauge drops and the ball in the flow meter rises, 
this means you have a leak and you will need to re-smoke the 
vehicle.

 

 

Continued on next page 

Содержание CERAMIHEAT smoke monster Pro S 25

Страница 1: ...Smoke Leak Locator User Manual For Models Pro S 25 Pro S 75 Pro S 600T and Pro S2000HD Ceramic Heating Technology www proflex plus com ...

Страница 2: ...sizes x 17 Cone Adaptor x 1 EVAP Port Removal Tool x 1 EVAP Port Adapter Hose x 1 Bottle Oiler x 3 Hook x 1 Packing List for Pro S 600T Main Unit x 1 All in 1 Bladder Blocker x 2 Cap Stopples Varied size x 17 Cone Adaptor x 1 EVAP Valve Removal Tool x 1 EVAP Port Adapter Hose x 1 Bottle Oiler x 3 Packing List for Pro S 2000HD Main Unit x 1 HD Bladder Blocker x 2 Smoke wand x 1 Safety chain and Hal...

Страница 3: ... cycle will begin Open the airflow dial on the airflow meter You can control the amount of smoke by opening or closing the airflow dial on front Within 1 minute smoke will appear Unit is now ready to use for diagnostic purposes Note Pressing the red button again within a working cycle will stop the smoke mode and revert to the air mode immediately There can be some smoke residue in the hose DIAGNO...

Страница 4: ...the 2 LEDs will blink for a few seconds After the led lights finish blinking they will turn off and the unit will be in EVAP air mode By pushing the Smoke Mode button the LED light will be lit and unit is ready to start 5 minute smoke cycle Find the leaks and make necessary repairs OPERATING IN AIR LEAK DECAY MODE both EVAP TURBO Switch unit back to Air Mode and start pressurizing the vehicle Once...

Страница 5: ...econds This function is to prepare switch the unit to Turbo Mode By pushing the Smoke Mode button the LED light will be lit and unit is ready to start 5 minute smoke cycle use the Bladder Blocker s provided inside the accessory case to block the turbo both single or dual turbos Find the leaks and make necessary repairs To check for Air Leak Decay see above instructions ...

Страница 6: ...d power toggle switch on the front of unit 8 The unit is in Air Mode until you select the Smoke Mode 9 Start the smoke mode operation by pushing the chrome on button on the front the red LED light indicator should be on This will start the Smoke Mode for a 10 minute working cycle NOTE DO NOT EXCEED 20 PSI IN SMOKE MODE 10 Adjust the test pressure using the large dial between the gauges the top gau...

Страница 7: ...perly filled with air and desired PSI needed 3 Turn RED rocker switch to off and check gauge to see if the pressure is falling and the ball in the flow meter is rising If this happens you still have a leak in the system You will need to re smoke the system to find another leak 4 If the pressure is holding the leak is fixed Unit is not applicable for EVAP SYSTEMS ...

Страница 8: ...in those marks There is a possibility that this unit is inapplicable to some of the vehicle models or systems listed in the diagnosis section due to different countries areas and or years Do not hesitate to contact PROFLEX if you come across such questions We are to help you solve the problem as soon aspossible Disclaimer To take full advantage of the unit you should be familiar with the engine Al...

Страница 9: ... trademark service mark domain name logo or company name Copyright Information Copyright 2012 by PROFLEX Distribution Inc referred as PROFLEX All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of PROFLEX The informatio...

Страница 10: ...stated herein Lifetime Warranty for CERAMIHEAT heater In addition to above PROFLEX offers a Limited Lifetime Warranty for material and workmanship of the CERAMIHEAT heater to the original purchaser of any PROFLEX product that is built with the CERAMIHEAT technology This warranty is valid to the original purchaser who has purchased the product from an authorized dealer and for as long as the origin...

Страница 11: ...11 WARRANTY RECORD Brand Name SMOKE MONSTER Model Serial Date of Purchase Dealer of Purchase Company Name Address Contact Name E Mail Phone THANK YOU FOR PURCHASING THIS PROFLEX PRODUCT ...

Страница 12: ... Distribution Inc 63 Lawrence Paquette Drive Champlain New York 12919 For warranty repair or return in CANADA Proflex Distribution Inc 65 Brunswick Montreal Quebec Canada H9B 2N4 A return authorization number RMA must be obtained before returning any merchandise under warrant ...

Отзывы: