8
Events
In KDC1905 system, locking control, OC outputs and acoustic signal generation is based on the event model. Events
are: selection of lock code, selection of P1 or P2 buttons in the uniphone (separate events, depending on the decoder
state), use of ID, request for feedback and pressing an external button. For example, the opening of lock can be
called up with push-button P1 or P2 during a conversation, or by using an ID, but the OC output control (e.g.
staircase lighting) can also be “added” to the use of an ID.
Each event (except for ANSWER event) is generated by one of the cassettes in the system, which enables to
change system operation depending on the “active” cassette (for example, using the ID in cassette no. 1 opens the
lock attached to it and controls the OC output for staircase lighting, while using the same ID in cassette no. 2 will
only open the gate).
Parameters needed to connect events to selected leads are described in Tables: 12 for locks, 13 for OC and 34
for beeper. In most cases the beeper settings will overlap with settings of triggering the lock, but this is not the rule .
8.6
Definitions of events
There are several types of events in the system. The list below describes each of them :
•
press AUX – press the external “lock button”. It can open the lock, control the OC, generate an acoustic
signal and trigger a conversation with the property
•
entering the lock code (0) – (opening the door with lock code) can control the locks and outputs OC and
generate a beeper
•
use of RFID ID (0) – controls locks and OC outputs, generates an acoustic signal
•
press P1 key – press the P1 button in the device during a call, triggers OC locks and outputs and generates a
beeper
•
press P2 key – like selecting the P1 key
•
ANSWER from the device – pressing the P1 key in the device while system is idle, by default it calls
feedback, it can also trigger OC outputs and locks, and generates a beeper
•
office function – action carried out after connection with the uniphone with the handset raised and the
“office” mode activated for this number, triggers OC locks and outputs, and generates a beeper
•
keyboard usage – triggers only OC. The event can be used to turn on the relay from the lighting . Beeper
generation is independent of beeper connection parameters and is always generated in the local keyboard.
Events that occurred in the software version 7r00:
•
P5 – selection of the P1 key during the device’s downtime
•
P6 – selection of P2 during the device’s downtime
•
use of RFID after setting the appropriate flag of premises (1) – event analogous to the use of rfid, but
generated only for premises with the appropriate flag set
•
use of the lock code after setting the flag of premises (1) – event analogous to the use of lock code, but
generated only for premises with the appropriate flag set
Содержание KDC1905