23
Semi-dry type
Oil bath type
WING NUT
WING NUT
AIR CLEANER
COVER
AIR CLEANER
COVER
ELEMENT
ELEMENT
Unscrew the wing nut, remove the air
cleaner cover and remove the element.
Wash the element in a nonflammable
or high flash point solvent and dry it
thoroughly.
Soak the element in clean engine oil
and squeeze out the excess oil.
Unscrew the wing nut, remove the air
cleaner cover and remove the element.
Empty the oil from the air cleaner case
and wash out any accumulated dirt
with nonflammable or high flash point
solvent. Dry the case.
Fill the air cleaner case to the level
mark with the same oil that is recom-
mended for the engine (see engine oil
recommendations on page
).
Wash the element in a solution of
household detergent and warm water,
then rinse thoroughly, or wash in non-
flammable or high flash point solvent.
Allow the element to dry thoroughly.
Soak the element in clean engine oil
and squeeze out the excess oil. The
engine will smoke during intial start-
up if too much oil is left in the element.
Reinstall the element and the cover.
Reinstall the air cleaner element and
the cover.
1.
2.
3.
4.
1.
2.
3.
4.
5.
6.
6
Содержание 52400043
Страница 1: ...52400043 V7 DE GB FR Betriebsanleitung Operating Instructions Instructions d emploi SH 2500 UNI B...
Страница 34: ......
Страница 38: ......
Страница 39: ...Betriebsanleitung Vakuumpumpe TFK 12 Vakuumpumpe TFK 12...
Страница 82: ......
Страница 115: ......
Страница 119: ......
Страница 120: ...Operating Manual Vacuum Pump TFK 12 Vacuum Pump TFK 12...
Страница 130: ......
Страница 164: ......