Operating Instructions
SH 2500-UNI-B
Maintenance and care
29 / 32
V7
GB
10.3
Vacuum pump (TFK 12)
See vacuum pump operating instructions (in appendix)
10.4
V-Belt
●
Check the V-belt tension monthly.
●
The V-belt must not protrude more than 1cm or it will need to be rest retched.
●
Procedure:
●
Replace the protective cover
●
Release the 4 hex bolts (1)
●
Release the locknuts of the hex bolts (2)
●
Tighten the hex bolts (2) until the correct V-belt tension is reached.
When tightening be sure that the V-belt wheels are aligned.
●
Tighten the locknuts of the hex bolts (2)
●
Replace the protective cover