Chapter 4 Installation and Wiring
4-7
4.2
Wiring
This section describes the procedures and precautions to install the PL unit.
4.2.1
Connecting the Power cord
Connect the power cord to the power plug on the rear of the PL unit. The power plug can be removed from
Socket part of the PL unit.
To avoid an electric shock, prior to connecting the PL unit’s power cord terminals to the
power terminal block, confirm that the PL unit’s power supply is completely turned OFF, via
a breaker, or similar unit.
The PL is designed to use AC100V/240V input. Supplying a power voltage other than that
specified will damage the power source and the PL unit.
When the FG terminal is connected, be sure the wire is grounded to avoid an electric shock
at breakdown.
• When the FG terminal is connected, be sure the wire is grounded. Not grounding
the PL unit will result in excess noise and vibration.
• The SG and FG terminals are connected internally in the PL unit.
• When connecting the SG wire to another device, be sure that the design of the
system/connection does not produce a shorting loop.
L
N
FG
Rear Side
Power Plug