PL-6930 / PL-7930 Series User Manual
8-4
8.3
Periodic Inspection Items
Be sure to inspect the PL periodically to ensure it is in good working condition.
Ambient environment check points
Is the ambient temperature within the specified range?
•
Is the ambient humidity within the specified range (10%RH to 85%RH)?
•
Is the atmosphere free of corrosive gas?
Electrical specifications check
•
Is the voltage adequate (AC85V to AC265V, 50Hz to 60 Hz)?
Installation check points
•
Are all connection cables firmly connected?
•
Are any bolts or screws loose?
•
Are there any flaws or tears on the moisture resistant gasket?
Display check
•
Is the display bright enough?
Ambient Operating
Temperature
PL693*-T41, PL793*-T41
Model without FAN
(CPU: CeleronM 1.3GHz)
5 °C
to 40 °C
(When using HDD)
0 °C
to 40 °C
(When NOT using HDD)
PL693*-T42, PL793*-T42
Model attached FAN
(CPU:PentiumM1.6GHz or
CeleronM 1.3GHz)
5 °C
to 50 °C
(When using HDD)
0 °C
to 50 °C
(When NOT using HDD)
•
When the PL’s backlight needs to be replaced, please contact your nearest authorized service
center for prompt service