14
EmpyrE ElItE InstallatIOn and OpEratIOn manual
InsTallaTIon
Optional Heat Exchanger
Stainless Steel Water to Water Heat
Exchanger, Figure 2, can be used in place of
a side arm.
COLD
WATER
MIXED
WATER
TEMPERING VALVE
Hot Water
Used for
bleeding air
WATER HEATER
Use for
filling system
Supply from
Empyre Elite
furnace
To domestic
heating
system
Water heater drain
CAUTION
:
Do not eliminate
the existing
temperature relief
valve
SIDE ARM HEA
T EX
CHANGER
NOTE:
Keep bottom loop (and side arm) as low as possible.
PUMP
BALL VALVE
THERMOMETER
BOILER DRAIN
TEMPERING OR
MIXING VALVE
SYMBOLS INDEX
side arm Installation
To domestic
heating system
Hot water in
from
Empyre Elite
furnace
To top of hot water tank
Figure 1
Figure 2
From bottom of hot water tank
Have a qualified electrician and
plumber check to ensure all
connections to the furnace are
made in accordance with the
manufacturer’s specifications and
performed by qualified, licensed
personnel in accordance with
local building codes.
ImpOrtant
When hooking
up the Empyre
Elite to a domestic hot
water heater, a tempering
valve must be installed,
to prevent scalding hot
water from reaching the
hot water outlets.
Valve