1.
Turn off the electric and gas supply to the fire feature.
2.
Remove any fire media that is on top of the burner plate.
3.
Unscrew the 2 screws holding the pilot assembly in place.
4.
Carefully pick up the burner plate and turn upside down.
5.
Unplug the 4-pin connector from the control box to the pilot assembly.
6.
Disconnect the flexible pilot gas hose from the control box.
7.
From the top of the burner plate, gently pull up the pilot assembly and remove from the plate.
Replacing the Pilot Orifice
Pilot Head Assembly
1.
Disconnect the flexible gas hose from the pilot. Be careful not to put pressure on the ceramic
flame sensor; damaging the flame sensor will render the flame sensor inoperable.
2.
Remove the flare fitting from the pilot assembly.
3.
Remove the pilot orifice from the pilot assembly and replace with the new one.
4.
Hand-tighten the orifice until seated. Use wrench to secure but do not over-tighten.
5.
Hand-tighten the flare fitting until snug.
6.
Take flexible pilot hose and tighten onto the flare fitting. Once snug, use wrench to tighten
the hose fitting.
Replacing the Burner Orifice
PILOT HOOD
PILOT SENSOR
GROUND WIRE
PILOT ORIFICE
PILOT GAS HOSE
FLARE FITTING
PILOT PLATE
Содержание Hardscapes Moderno 5
Страница 1: ...INSTALLATION OPERATION MAINTENANCE MANUAL For model PH Ignite 12VAC Auto Burner Ignition System...
Страница 20: ...Section 6 Wiring Layout Diagrams...
Страница 23: ......