2.3 GAS & ELECTRONIC REQUIREMENTS
INPUT VOLTAGE: 120 VAC/60 HZ to transformer
OUTPUT VOLTAGE (transformer to appliance): 12 VAV/60 HZ
GAS TYPE: Natural Gas Propane Gas
GAS PRESS 7 inches Water Column 11 inches Water Column
GAS INPUT FLOW 85,000 BTU/HR 85,000 BTU/HR
RECOMMENDED CLEARANCES TO COMBUSTIBLE SURFACES: SIDES: 4 FT TOP: 6 FT
Note:
Check with your gas supplier to verify gas flows and pressures available at the location of your
installation. In many cases utility companies will install larger meters at no charge to accommodate
larger flows.
WARNING
THIS PRODUCT OPERATES WITH 12 AC INPUT
DO NOT ATTEMPT TO CONNECT 120 VACS DIRECTLY TO THE APPLIANCE FOR IT
MAY CAUSE PERMANENT DAMAGE
2.4 PRODUCT CONTENTS
PART NAME
QTY
BURNER & BURNER PLATE
1
PILOT ASSEMBLY (PILOT BURNER, IGNITOR, SENSOR $ HOOD)
1
IGNITION CONTROL BOX
1
HEAT SHIELD
1
HEAT SHIELD JAM NUT
1
ORIFICE SET (BURNER & PILOT)
1
TRANSFORMER (120VAC/12VAC)
1