![Princeton GTIB-30 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/princeton/gtib-30/gtib-30_installation-manual_1603033019.webp)
GTIB-30 Installation Manual-UL
4411-0011, Rev 2.0
19
2.1 System Overview
The GTIB-30 is an extremely versatile state of the art multi-port energy management
converter system. The GTIB-30 can be connected to batteries, solar PV arrays, and
utility grids. Unlike most conventional inverters and renewable energy systems, the
GTIB-30 is designed to support and strengthen the utility grid instead of being a
burden on it. It is therefore compatible with next generation smart and micro grids.
These new power systems enable a much higher penetration of renewable energy
than conventional inverter systems would allow and therefore the GTIB-30 helps to
facilitate technical solutions to some of the world’s most urgent environmental
problems.
In an on-grid application, the loads connected to the GTIB-30 Load Port are supplied
directly from the utility (as long as the grid is available). When the GTIB-30
’
s DC port is
configured for bi-directional power exchange with a DC power source or DC energy
system, it charges its batteries from the utility grid. When the batteries are full, the
GTIB-30 supplies all of the energy to the loads. At any stage, the operator can request the
GTIB-30 to provide additional energy and supplement the utility grid by feeding energy
from the batteries into the grid. (See User Manual) When the DC Port is configured for
PV operation, the GTIB-30 can draw power from a connected PV array and supply it to
the loads or optionally export it to the grid.
Additionally, the GTIB-30 also allows solar PV energy to be supplemented with
combustion generators and other AC sources.
2.1.1 Power Ports
The GTIB-30 Inverter has one DC port (battery or PV) and one or two (optional) AC
power ports (grid and load) giving the GTIB-30 a total of three power ports. In this
manual, the GTIB-30 is often symbolically represented by a diagonally divided
square where one half represents the AC ports and the other half represents the
DC port (battery or PV). This symbolic representation of the GTIB-30 is shown in
the center of Figure 1.
2.1.1.1
DC Port
The DC port can be either used for a battery bank or for connecting a PV array to the
GTIB-30. The battery port is a two wire DC port used to connect a battery bank to
the GTIB-30. The PV Port is a two wire DC port used to connect a PV array to the
GTIB-30.
1
Содержание GTIB-30
Страница 1: ...Clean power made simple GTIB 30 Installation Manual ...
Страница 2: ...www princetonpower com 4411 0011 Rev 2 0 April 1st 2014 ...
Страница 11: ...About this Manual 4411 0011 Rev 2 0 xi This page intentionally left blank ...
Страница 15: ...Contents 4411 0011 Rev 2 0 15 This page intentionally left blank ...
Страница 16: ...1 Introduction ...
Страница 18: ...2 System Overview and Configurations ...
Страница 31: ...3 Pre Installation ...
Страница 36: ...GTIB 30 Installation Manual UL 36 4411 0011 Rev 2 0 This page intentionally left blank ...
Страница 37: ...4 Wiring Instructions ...
Страница 56: ...GTIB 30 Installation Manual UL 56 4411 0011 Rev 2 0 This page intentionally left blank ...
Страница 57: ...5 Commissioning Sequences ...
Страница 61: ...GTIB 30 Installation Manual UL 4411 0011 Rev 2 0 61 This page intentionally left blank ...
Страница 62: ...A GTIB 30 kW Specifications ...
Страница 65: ...GTIB 30 Installation Manual UL 4411 0011 Rev 2 0 65 This page intentionally left blank ...
Страница 66: ...B Return Material Authorization Contact and Product Information ...
Страница 69: ...GTIB 30 Installation Manual UL 4411 0011 Rev 2 0 69 This page intentionally left blank ...