100962 G PUBLICATION DATE 24 JUN 2008.DOC
PROGRAMMING MANUAL
33
•
Some washing machines function with external Liquid soap
supplies and others do not.
•
If external liquid soap supplies are connected to the washing
machine, the selection must be Yes.
•
If No is selected, then No external liquid soap supplies can
be programmed at the Program menu.
•
Yes : Liquid Supply Signals enabled.
No : Liquid Supply Signals disabled.
•
Confirm by pressing the ENTER button.
•
Soap Supply signals will only be started when the
pre-set water level has been reached.
•
Default value :
- 0 units for top soap Dispensing machines.
- 10 units for front soap Dispensing machines.
•
The value can be programmed between 0 and the minimum
programmable water level. See water consumption table.
•
Confirm by pressing the ENTER button.
Front soap hopper machines Only.
•
The liquid soaps supplying the manifold can be flushed
by an extra water inlet that is mounted on the manifold of the
soap dispensing system.
This extra water supply is called : LS-Flush
(Liquid Soap-Flush)
•
Both menus are only visible when in the configuration menu
“Liquid Supply Signals” is set Yes.
•
The time to flush, before the liquid supplies are switched On,
can be set to: 0-15 seconds.
•
The time to flush, after the liquid supplies are switched Off,
can be set to: 0-99 seconds.
•
When both time settings are 0 seconds then the manifold
will not flush water at all while liquid soap supply is pumped
into the manifold.
•
1 second Pre-Time and 5 seconds After-Time are the
default values. (FF120=10”).
•
Confirm by pressing the ENTER button.
•
Press the ARROW LEFT or RIGHT button to
select Celsius or Fahrenheit, depending if you prefer that the
temperature is displayed in degrees Celsius or degrees
Fahrenheit.
C:Liquid Supply
Signals: No
C:Temperature:
Celcius
C:LS-Flush
After-time : 05 Sec
C:LS-Flush
Pre-time : 01 Sec
C:Minimum Level
Start Supply : 0