3.4. PROGRAMMING THE FUNCTIONS
T
Limits
To ensure the correct functionality of the washing machine you have to program values within
certain limits.
If you program a value that falls below the minimal or above the maximal programmable limit
then the new value will not be accepted and the previous value stays valid.
T
Programming the Water Temperature
Limits
- Minimum value : 1 °C
- Maximum value : 45°C for the PREWASH and SOAK and 92°C for the WASH sequence.
- For RINSE, FINAL RINSE, FLUSH and SPRAY no Temperature can be programmed.
T
Programming the Inlet valves
Depending the programmed temperature the inlet valves are suggested.
While the tub is filling with water, the computer controls the water temperature. By switching on
and off the hot and cold water inlet valves the correct water temperature is obtained.
For machines with a Top Soap Hopper you have to consider that by programming the inlet
valves, at the same time, you are also selecting the soap Box at which the soap must be added.
If you want to program a wash sequence with :
- Cold Water :
only Cold Inlet Valves must be programmed
- Warm or Hot water :
Cold and Hot Inlet Valves must be programmed
Top Soap Hopper washing machines :
MFR
The cold water inlet valves
Inlet Valve 2 corresponds with Soap Box A (Prewash)
Inlet Valve 5 corresponds with Soap Box B (Wash)
Inlet Valve 1 corresponds with Soap Box C (Final Rinse)
Inlet Valve 6 is a direct Inlet Valve and speeds up the water fill process
The hot water inlet valves
Inlet Valve 4 corresponds with Soap Box B (Wash)
Inlet Valve 3 is a direct inlet Valve and speeds up the water fill process
How to select inlet valves : EXAMPLE
For a Prewash :
Programmable temperature:
1 - 45°C
Inlet Valve 2 (cold)
Soap box A
+ Inlet Valve 3 (hot) and/or 6 (cold)
Direct Inlets
For a Wash :
Programmable temperature:
1 - 92°C
Inlet Valve 4 (hot) and/or 5 (cold)
Soap box B
+ Inlet Valve 3 (hot) and/or 6 (cold)
Direct Inlets
For a Rinse :
Inlet valves 2 + 5 + 6 (cold)
No Soap is added
For a Final Rinse : Inlet valve 1 (cold hard) (or cold soft)
Soap box C
+ Inlet valve 6 (cold soft)
only if No cold hard water for Inlet 1