Terminal Block Specifications
The Bell Controller device has a removable terminal block on the bottom of the device. The terminal block has two independent relay
contact input connections and two dry contact input connections.
The relay connections support for either normally open( NO) or closed (NC) operation. A relay triggers the bells to ring at the schedules
set in its assigned zone within your OneVue account.
The dry contact closure inputs can be connected to a standalone switch or button to activate a bell manually - commonly referred to as
an impromptu bell. An impromptu bell is a bell event that is not scheduled in OneVue.
Terminal block connections (pin out) specifications
P1: Input 1 for impromptu bell (switch or button input) – dry contact closure input pair sounds bell(s) on both relays immediately when
activated
P2: Input 2 for impromptu bell (switch or button input)
P3: Relay 1 Normally Closed Contact Input
P4: Relay 1 Common Contact Input
P5: Relay 1 Normally Open Contact Input
P6: Relay 2 Normally Closed Contact Input
P7: Relay 2 Common Contact Input
P8: Relay 2 Normally Open Contact Input
Terminals accept wire gauge from 16-26 AWG.