![Primes FocusMonitor FM+ Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/primes/focusmonitor-fm/focusmonitor-fm_operating-manual_1601726016.webp)
FocusMonitor FM+
35,0(6
16
Revision 03/2019 EN
7.2
Preparation
Before installation, check the available space, especially to ensure that there is enough room for the move-
ment range of the FocusMonitor FM+.
The device must be firmly assembled and must be mounted with screws (see chapter 7.5 on page 20). Its
symmetrical construction allows the device to be set up and mounted overhead without additional aids. The
position and diameter of the mounting holes on the top/bottom are identical.
NOTICE
Damage/Destruction of the device
Obstacles in the movement range of the FocusMonitor FM+ can lead to collisions and dam-
age the device.
X
Keep the movement range free of obstacles (cutting nozzle, pressure rolls, etc.).
Please note that the measuring head automatically moves into its resting position after the
power supply has been turned off and on again or following a reset. Keep this area clear.
z=120 mm
y= max. 22 mm
Fig. 7.3:
Movement range of the measuring head
In the LaserDiagnosticsSoftware LDS you have the option to restrict the movement range of the
FocusMonitor FM+ (locked area, for further informationen see chapter 11.4.4 on page 32).
DANGER
Fire and explosion hazards due to scattered or directed laser radiation
When the FocusMonitor FM+ is being operated, the irradiation must be fully absorbed be-
hind the measurement zone. Fire bricks or other partly-absorbing surfaces are not suitable.
X
Use an adequate absorber. Dependent on the application, PRIMES offers suitable absorbers,
such as the PowerMonitor PM 48/100.
X
Don’t store any flammable materials or highly flammable substances at the measuring loca-
tion.
NOTICE
Damage/Destruction of the absorber (e. g. PowerMonitor PM 48/100)
If the focused laser hits the absorber, it may be destroyed.
X
Ensure there is enough distance between the FocusMonitor FM+ and the absorber (the max-
imum permissible power density of the absorber must not be exceeded).