
BEST BOY
®
HP SPOT LUMINAIRE USER MANUAL
57
Gobo out of zero range
When zeroing gobo wheels, the wheel is
too far away from zero to set the position
Move wheel closer to home position
before zero command
Head Fan Error
Fan not running properly
Check fan
In Free Mode: Can’t Lock
Free mode is enabled
Use pan/tilt menu to change from "free"
to "lock"
Lamp Off
Fan Error: Cannot strike lamp while any
fan is in error state
Check fan, fan cabling
Lamp Off: Over Temperature
Head temperature too high
Check fans
Lamp over threshold
Lamp hours above recommended
maximum
Change lamp
Must Unlock via Free Option
Lock is enabled
Use pan/tilt menu to change from "lock"
to "norm"
Plenum Fan Error
Fan not running properly
Check fan
PMD Motion Error
Mechanism's actual position is too far
from its commanded position
Check mechanism motion
Framing Motor Disabled
Framing not running properly
Recalibrate, check mechanism motion
Stack Fan Error
One or more stack fans not running
properly
Check fan, fan cabling
Temp over threshold
Temperature too high
Check fans/filters
Tip Fan Error
Fan not running properly
Check fan
UPE Fans Error
Upper Enclosure fans not running
properly
Check fan, fan cabling
Yoke Fan Error
Fan not running properly
Check fan
Error Code
Explanation
Solution
Содержание BEST BOY
Страница 1: ...SOFTWARE VERSION 2 1 WWW PRG COM BEST BOY HP SPOT LUMINAIRE USER MANUAL...
Страница 11: ...1 DESCRIPTION This chapter contains an overview of luminaire features and components FEATURES COMPONENTS...
Страница 89: ...A TECHNICAL SPECIFICATIONS BEST BOY HP SPOT LUMINAIRE BEST BOY ROAD CASE...
Страница 93: ...B GLOSSARY This glossary provides useful terms associated with operating the Best Boy HP Spot Luminaire...
Страница 98: ...90 BEST BOY HP SPOT LUMINAIRE USER MANUAL Notes...
Страница 99: ...Best Boy HP Spot Luminaire User Manual Version as of March 25 2015 PRG part number 02 9817 0001...
Страница 100: ...Production Resource Group LLC Dallas Office 8617 Ambassador Row Suite 120 Dallas Texas 75247 www prg com...