12
BEST BOY
®
HP SPOT LUMINAIRE USER MANUAL
DMX512 Male Termination Connector
A male XLR DMX512 termination connector is required at the last luminaire (or "far end of
the line") to prevent signal reflections. Signal reflections may cancel out the signal at
certain line lengths, resulting in errors. The terminator is also necessary for software
downloads and running tests on multiple luminaires.
To construct your own connector,
you will need the following components:
+
5-pin, male XLR connector.
+
120 ohm resistor.
Note:
A male termination connector is also available as an accessory from PRG. See
Ethernet Cables
The Best Boy HP Luminaire is equipped with two RJ-45 type connectors for Ethernet input/output. Ethernet cabling
should follow these guidelines:
+
Ethernet cable assemblies must match the CAT5e specification.
+
Regular or crossover cables are acceptable.
+
Both EtherCon® and RJ-45 connectors are acceptable.
Ethernet Bypass
A relay allows Ethernet signals to pass through daisy-chained luminaires even if power is removed.
Solder resistor
across pins 2 & 3
1
2
3
4
5
Содержание BEST BOY
Страница 1: ...SOFTWARE VERSION 2 1 WWW PRG COM BEST BOY HP SPOT LUMINAIRE USER MANUAL...
Страница 11: ...1 DESCRIPTION This chapter contains an overview of luminaire features and components FEATURES COMPONENTS...
Страница 89: ...A TECHNICAL SPECIFICATIONS BEST BOY HP SPOT LUMINAIRE BEST BOY ROAD CASE...
Страница 93: ...B GLOSSARY This glossary provides useful terms associated with operating the Best Boy HP Spot Luminaire...
Страница 98: ...90 BEST BOY HP SPOT LUMINAIRE USER MANUAL Notes...
Страница 99: ...Best Boy HP Spot Luminaire User Manual Version as of March 25 2015 PRG part number 02 9817 0001...
Страница 100: ...Production Resource Group LLC Dallas Office 8617 Ambassador Row Suite 120 Dallas Texas 75247 www prg com...