TECHNICAL INFORMATION
5 - 15
Main
Code
Sub
Code
Description
Do Not
Shift
Light
Inhibited Operation Description
32
33
C3 pressure switch open, 3rd range
Yes
DNS, Lock in current range (3rd)
32
55
C3 pressure switch open, 5th range
Yes
DNS, Lock in current range (5th)
32
77
C3 pressure switch open, R range
Yes
DNS, Lock in current range (R)
33
12
Sump oil temperature sensor, low
No
Use default value of 200
ø
F (93
ø
C)
33
23
Sump oil temperature sensor, high
No
Use default value of 200
ø
F (93
ø
C)
34
12
EEPROM, factory cal. compatibility number
wrong
Yes
DNS, SOL OFF (Hydraulic default)
34
13
EEPROM, factory calibration block checksum
Yes
DNS, SOL OFF (Hydraulic default)
34
14
EEPROM, Power Off Block checksum
Yes
Use previous location, or factory
calibration and reset adaptive
34
15
EEPROM, Diagnostic Queue Block
Checksum
Yes
Use previous location, or clear
diagnostic queue
34
16
EEPROM, Real Time Block Checksum
Yes
DNS, SOL OFF (Hydraulic default)
35
00
Power interruption (Code set after power
restored)
No
NONE (Hydraulic default during
interruption)
35
16
Real Time EEPROM Write Interruption
Yes
DNS, SOL OFF (Hydraulic default)
36
00
Hardware/Software not compatible
Yes
DNS, SOL OFF (Hydraulic default)
41
12
Open or short to ground, A solenoid circuit
Yes
DNS, SOL OFF (Hydraulic default)
41
13
Open or short to ground, B solenoid circuit
Yes
DNS, SOL OFF (Hydraulic default)
41
14
Open or short to ground, C solenoid circuit
Yes
DNS. SOL OFF (Hydraulic default)
41
15
Open or short to ground, D solenoid circuit
Yes
DNS, SOL OFF (Hydraulic default)
41
16
Open or short to ground, E solenoid circuit
Yes
DNS, SOL OFF (Hydraulic default)
41
21
Open or short to ground, F solenoid circuit
No
Lock-up inhibited
41
22
Open or short to ground, G solenoid circuit
Yes
DNS, SOL OFF (Hydraulic default)
41
23
Open or short to ground, H solenoid circuit
No
Retarder allowed, differential lock
inhibited
41
24
Open or short to ground, J solenoid circuit
No
Low and 1st inhibited
41
25
Open or short to ground, K solenoid circuit
No
K solenoid operation inhibited
41
26
Open or short to ground, N solenoid circuit
No
Low and 1st inhibited
42
12
Short to battery, A solenoid circuit
Yes
DNS, Lock in a range
42
13
Short to battery, B solenoid circuit
Yes
DNS, Lock in a range
42
14
Short to battery, C solenoid circuit
Yes
DNS, Lock in a range
42
15
Short to battery, D solenoid circuit
Yes
DNS, Lock in a range
42
16
Short to battery, E solenoid circuit
Yes
DNS, Lock in a range
42
21
Short to battery, F solenoid circuit
No
Lock-up inhibited
42
22
Short to battery, G solenoid circuit
Yes
DNS, Lock in a range
42
23
Short to battery, H solenoid circuit
No
Retarder allowed, differential lock
inhibited
42
24
Short to battery, J solenoid circuit
No
Low and 1st inhibited