STARTING AND STOPPING PROCEDURE
4 - 11
5. Central A/C - heating
Temperature
control
Push down
Central A/C - heating
switch to acti-
vate main A/C-heating system. Regulate tem-
perature for
A/C
or
heating
mode in central sec-
tion by turning control clockwise to increase tem-
perature or counterclockwise to decrease it. A
red LED located in center console under the in-
side temperature thermometer will light when the
heating
mode is operating, while
A/C
mode and
the
dehumidification
function will be indicated by
a green LED.
Only a slight movement of knob is generally suf-
ficient to change temperature setting. Once tem-
perature is selected, system will automatically
maintain it within close limits.
Note:
The two LEDs may be illuminated simul-
taneously when heating and dehumidifying are
required. To maintain ambient temperature, turn
control until red LED lights out. However, the
green LED may remain on if the dehumidifying
mode is operating.
7. Fresh air damper switch
Push down rocker switch to close partially the
fresh air damper. Under extreme temperature
conditions only, it can be closed or partially
closed according to the inside temperature
reached in the vehicle, to block the addition of
ambient air and heat or cool only air that is in the
vehicle. As soon as extreme heating or cooling is
no longer required, the damper should be re-
opened.
Main Breakers
All electric circuits are protected by circuit breakers
of the
"Manual reset"
type. The main circuit break-
ers, as well as those protecting A/C system, are
located in the main power compartment, on R.H.
side of the vehicle, behind the tag axle.
BREAKERS
06049
CB1
Ignition
12 volts
40 amps
CB2
Hot Wire
12 volts
30 amps
CB3
Rear Junction Box
12 volts
40 amps
CB4
Front Junction Box
12 volts
40 amps
CB5
Hot Wire
24 volts
30 amps
CB6
Rear Junction Box
& Starter Relay
24 volts
90 amps
CB7
Front Junction Box
& Inverter Comp.
24 volts
90 amps
CB8
A/C Junction Box
& Evaporator Fan
24 volts
150
amps
CB9
A/C Condenser
Fan Motor
24 volts
150
amps
Note:
If one of the main breakers has to be re-
set, it may be necessary to use a large object to
push in breaker
(do not use the object to hit the
breaker)
since they require considerable force to